Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
CROSS-SECTIONS & PARTS LIST ..........14 - 16 CONSTRUCTION DETAILS .............17 WARRANTY & RETURNED GOODS ..........19 Other brand and product names are trademarks or registered trademarks of their respective holders. Deming® is a registered trademark of Crane Pumps & Systems, Inc. 1996, 12/06 Alteration Rights Reserved...
Crane Pumps & Systems, Inc. is not responsible for pressures. It is recommended that a high case temperature losses, injury, or death resulting from a failure to observe switch or pressure relief valve be installed on the pump body.
Systems Service Department in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & Systems Canada, Inc., Position unit on foundation and level the base plate, Bramton, Ontario, (905) 457-6223. using rectangular metal blocks and shims, or wedges having a small taper.
Page 5
4. FLEXIBLE COUPLING ALIGNMENT A fl exible coupling should not be used to compensate for misalignment of the pump and driver shafts. The purpose of the fl exible coupling is to compensate for temperature changes and to permit end movement of the shafts without ANGULAR interference with each other, while transmitting power from MISALIGNMENT...
There is always uneven fl ow in an elbow when it is WARNING - Coupling guards must be used to installed in any position other than a vertical position. This avoid serious injury to operating personnel. unequal fl ow allows more water to enter one side of the impeller than enters the other side causing a reduction in capacity and effi...
A pump operating under a suction lift may be primed by The following important items should be checked as pump any of the following methods, as may be best suited to the is started and placed in operation. conditions. The discharge valve should be closed during priming operation.
Page 9
2. PACKING BOX 14. Using overhead lifting device, hook onto rotating The packing glands should be adjusted occasionally to assembly with nylon straps or rope, to not scratch shaft. Remove bolts holding bearing housing to insure proper packing lubrication. A slow dripping through pump casing.
Page 10
2. Install shaft sleeves. Be sure good hub gaskets are 20. If new casing half gaskets are to be installed, place in place on sleeves, to seal between sleeve and them onto lower half and trim to fi x. CAUTION: Do impeller.
Page 11
32. Trim the casing half gaskets fl ush with casing at end FOOTNOTE: The rotating assembly can be adjusted by of stuffi ng box using a putty knife, fi le, etc. loosening the three bolts that holds the bearing housing to 33.
Page 12
TABLE 1 INSTALL WASHER AND BELLOWS ASSEMBLY PUMP SHAFT Fig. 5A with Fig. 5B Be sure the sleeve (or shaft) is clean and polished smooth GROUP SHAFT BALANCED before installing new part. SLEEVE “Y” SEAL “Z” Oil sleeve (or shaft) and the thimble with light oil, to allow the washer and bellows assembly to be easily pushed into 3 x 1-1/2 x 10 1-1/8...
E - LOCATING TROUBLE 5. Pump Takes Too Much Power a. Speed too high - Compare Pump and motor 1. No Liquid Delivered nameplates a. Pump not primed - See Priming b. Head lower than rating - pumps too much liquid. Check system requirements b.
2.500” 2.500” 2.812” Dia. Sleeve 1.750” 1.750” 2.000” Width of Bleed off Bushing 0.750” 0.750” 0.750” 5. Mechanical Seal Crane Type 1 (Unbalanced) 1-3/4 1-3/4 (225°F. MAX.) 6. Bearing Spacing 23.868 23.868 24.822 7. Shaft Overhang 4.250 4.250 4.625 8. Key Sizes At Coupling 1/4 sq.
Page 18
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Page 20
A Crane Co. Company START-UP REPORT General Information Pump Owner’s Name: __________________________________________________________ Address: ____________________________________________________________________ Location of Installation: _________________________________________________________ Contact Person: __________________________________Phone: _______________________ Purchased From: _____________________________________________________________ Nameplate Data Pump Model #: ___________________ Serial #: _____________________________________ Part #: __________________________ Impeller Diameter: ____________________________ Voltage: _________ Phase: _____ Ø...
Page 21
( ) Engineer: ____________________________ ( ) Operator: ________________________ ( ) Contractor: ____________________________ ( ) Other: ___________________________ All parties should retain a copy of this report for future trouble shooting/reference A Crane Co. Company 420 Third Street 83 West Drive, Brampton Piqua, Ohio 45356...
Need help?
Do you have a question about the Deming 5260 Series and is the answer not in the manual?
Questions and answers