Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notification. A Crane Co. Company...
WARRANTY REGISTRATION ......................22 START-UP REPORT ........................ 23 - 24 Other brand and product names are trademarks or registered trademarks of their respective holders. ® Deming is a registered trademark of Crane Pumps & Systems, Inc 2016 Alteration Rights Reserved...
IMPORTANT! - Crane Pumps & Systems, Inc. is not responsible for losses, injury, or death resulting from a WARNING! - DO NOT pump hazardous materials failure to observe these safety precautions, misuse or (flammable, caustic, etc.) unless the pump is specifically...
Crane Pumps & Systems, Inc., Service Department Away Fitting (BAF) in position. Temporarily secure the in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps guide rails in the upper mounting brackets and locate the & Systems Canada, in Brampton, Ontario, (905) 457-6223.
Page 5
B-4.1) Electrical Connections: B-3) Liquid Level Controls: When the electrical connections are made, the lead wires It is recommended to use a liquid level control system from the power cable should be stripped so that the ground that allows the on and off point to be separated by at least wire is at least two inches longer than the power leads.
Page 10
8 AWG, 6 AWG, 2 AWG 0 AWG / 18/5 - Dual Cord THREE PHASE 460-575 VOLT AC THREE PHASE 460-575 VOLT AC Power Cable Motor Lead ID Power Cable Motor Lead ID Green (Ground) Green Green (Ground) Green Black Black White White...
Page 11
WIRING DIAGRAM FIGURE 4 B-4.3) Overload Protection: Current sensing overloads must be provided in the pump A manual momentary start switch is required to prevent control panel and should be properly sized for the full load the automatic restarting of the motor when the thermostat current of the pump.
If a panel is to be supplied locally, it is recommended that should be investigated for moisture or damaged cables the Crane Pumps & Systems Pump Monitor Relay (P/N before proceeding. 134667) be used to perform the control circuit functions for the Temperature and Moisture Sensor Monitoring described C-3.3) Pump-Down Test:...
Service to any other components WILL VOID the warranty and explosion proof CAUTION ! - Handle seal parts with extreme certification. Any further work required contact Crane Pumps care. DO NOT scratch or mar lapped surfaces. & Systems.
SECTION: F REPLACEMENT PARTS F-1 ORDERING REPLACEMENT PARTS: When ordering replacement parts, ALWAYS furnish the following information: 1. Pump serial number and date code. (Paragraph F-4) 2. Pump model number. (Paragraph F-3) 3. Pump part number. (Paragraph F-2) 4. Part description. 5.
TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
Cross Sections IMPORTANT! - Service is limited to the following components becuase of the explosion proof rating: impeller, lower mechanical seal, volute and power cord. Service to any other components WILL VOID the warranty and explosion proof certification. Any further work required contact Crane Pumps & Systems. Vortex FIGURE 9 Enclosed FIGURE 10...
PARTS LIST ITEM PART NO. DESCRIPTION MATERIAL See Table No Resale Driver Assembly 127223 ♦ β π Screw, SHCS, M12 x 1.75 x 25, SS 18-8 SS See Table ƒ Impeller, Vortex Ductile Iron Q21-20-J8 ♦ Key, ¼ x ¼ x 1½”, 303 SS 303 SS 138310 ♦...
Page 21
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
A Crane Co. Company START-UP REPORT General Information Pump Owner’s Name: __________________________________________________________ Address: ____________________________________________________________________ Location of Installation: _________________________________________________________ Contact Person: __________________________________Phone: _______________________ Purchased From: _____________________________________________________________ Nameplate Data Pump Model #: ___________________ Serial #: _____________________________________ Part #: __________________________ Impeller Diameter: ____________________________ Voltage: _________ Phase: _____ Ø...
Page 24
( ) Engineer: ____________________________ ( ) Operator: ________________________ ( ) Contractor: ____________________________ ( ) Other: ___________________________ All parties should retain a copy of this report for future trouble shooting/reference A Crane Co. Company 420 Third Street 83 West Drive Piqua, Ohio 45356 Brampton, Ont.
Need help?
Do you have a question about the DEMING 7365 Series and is the answer not in the manual?