10-3. Indoor Unit
10-3-1. Installation Place
• A place which provides the spaces around the indoor unit as shown in the
diagram.
• A place where there are no obstacles near the air inlet and outlet.
• A place which allows easy installation of the piping to the outdoor unit.
• A place which allows the front panel to be opened.
CAUTION
CAUTION
• Direct sunlight to the indoor unit's wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner's manual)
Remote control
• A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment (This is necessary to prevent image disturbances or
noise interference).
• The location of the remote control should be determined as shown below.
(Side view)
7 m
Reception range
* : Axial distance
10-3-2. Cutting a Hole and Mounting
Installation Plate
Cutting a hole
(Rear piping)
100
60
(Bottom piping)
100
70
1. After determining the pipe hole position, drill the pipe hole (∅65 mm) at a
slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
(Top view)
Remote
control
Remote control
(Side piping)
45
: Pipe hole (ˇ 65 mm)
Mounting the installation plate and screw position
When the installation plate is directly mounted
on the wall
1. Securely fil t the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below fi gure.
3. Install the installation plate horizontally in the wall.
Installation plate
(Keep horizontal direction)
ˇ 5 mm hole
Clip anchor
(local parts)
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
• In case of block, brick, concrete or similar type walls, make ∅5 mm holes
in the wall.
• Insert clip anchors for appropriate mounting screws 7 .
- 73 -
(Unit : mm)
Wall
Floor
Anchor bolt
Projection
15 mm or less
7
Mounting screw
∅4 mm x 25 l
CAUTION