Toshiba RAS-B10J2FVG-E Service Manual page 36

Air conditioner split type
Hide thumbs Also See for RAS-B10J2FVG-E:
Table of Contents

Advertisement

Item
2. Indoor fan
motor control
[In starting and in stability]
• Until 12 minutes passed after operation start
FAN AUTO
• When 12 to 25 minutes passed after operation
start and room temp. is 3°C or lower than set temp.
FAN Manual
• Room temp. < Set temp. –4°C
(Table 2) Indoor fan air flow rate <Heating>
Fan speed
level
Operation flow and applicable data, etc.
In starting
RAS-B10J2FVG-E
HEAT
Fan speed
(rpm)
WF
UH
560
WE
H
560
480
WD
M+
WC
440
WB
M
400
WA
380
W9
L+
370
W8
L
320
W7
L-
260
W6
260
W5
UL
260
W4
260
W3
260
W2
SUL
240
W1
240
• When 12 to 25 minutes passed after operation start
and room temp. is higher than (set temp. –3°C)
• When 25 minutes or more passed after operation start
• Room temp. = Set temp. –3.5°C
RAS-B13J2FVG-E
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
528
600
570
528
580
552
443
520
486
408
470
435
366
460
426
342
410
376
334
400
366
282
340
300
216
270
228
216
270
228
216
270
228
216
270
228
216
270
228
198
250
210
198
240
198
- 36 -
Description
In stability
RAS-B18J2FVG-E
Fan speed
Air flow rate
(rpm)
(m3/h)
700
675
700
675
590
570
570
540
500
467
460
426
460
426
400
366
360
324
340
300
340
300
340
300
340
300
320
282
240
198

Hide quick links: