E. 調整感測器位置 / Adjusting the Sensor Position
⑴鬆開固鎖螺絲。
Loosen the locking screw.
⑵使用三用電表,量測感測器輸出電壓(DC)。
Use multimeter meter to measure the output DC voltage of sensor.
⑶旋轉調節螺絲,調整感測器位置,使感測器輸出電壓介於 DC0.5~0.6V,此時鎖緊固鎖螺絲固定感測器位置。
As shown in the following figure, rotate the adjustment screw to adjust the position of sensor, make the output DC
voltage of sensor lie within 0.5 ~ 0.6V, and then tighten the locking screw to secure the position of sensor.
註:鎖緊固鎖螺絲後,務必確認感測器輸出電壓仍然介於 DC0.5~0.6V 之間
As shown in the following figure, rotate the adjustment screw to adjust the position of sensor, make the output DC
voltage of sensor lie within 0.5 ~ 0.6V, and then tighten the locking screw to secure the position of sensor.
鬆開固鎖螺絲
Loosen the locking screw
調整調節螺絲
Adjust the adjustment screw
4
紅色探棒
黑色探棒
Red probe
Black probe