3. Operating Procedure
Operating Precautions
• Use this probe only with YOKOGAWA's oscilloscopes with probe
interface. Even with YOKOGAWA's oscilloscopes, this probe
can be used only when specified as a connectable accessory.
Also, use this probe only with standard or optional accessories
sold separately.
• Do not instantaneously or continuously apply a voltage
exceeding the following maximum voltage values between the
input and ground. Failure to follow this precaution may cause
accidents, such as electric shock or damage to the instruments.
Instantaneous voltage: ±100 V
Continuous voltage: ±35 V (DC + ACpeak)
• To use the probe, first connect to the oscilloscope and then to
the device under measurement. After use, turn off the power to
the device under measurement, disconnect the probe from the
device under measurement first, and then disconnect from the
oscilloscope.
• This probe is designed to measure the voltage difference
between two points on the device under measurement. It does
not electrically isolate the device under measurement from the
measuring instrument.
• When cleaning the probe, wipe with a piece of soft cloth to
prevent damaging the probe. Do not immerse the probe body in
liquid. Do not use abrasive cleaners or volatile solvents such as
benzine on the probe.
IM 701925-01EN
WARNING
CAUTION
5