5.2.2

Releasing the load:

Lower the load to a safe and clear, level surface, to
ensure that the load cannot slip or tip over.
Shift the bushing on the slide valve (A) back. The load is
released.
5.2.3

Lifting wet loads

The lifting device is not intended for picking up wet stone slabs. When picking up wet stone slabs, please observe
the following:
Remove water from the suction surface.
Carry out the following points after working with damp parts:
Lift up the lifting device. Make sure that the area around the suction plate is clear and that no items or water can be
drawn in.
Let the pump idle to run dry for at least 5 minutes.
Then switch off the device.
Open the condensate drain screw on the bottom of the storage container. Drain the water completely and tighten
the drain screw securely.