RECTIFIER
(See Fig. 1) Now we come to the most popular application of the diode: rectifcation. Rectifcation is the conversion of alternating
current (AC) to direct current (DC). This almost always involves the use of some device that only allows one-way fl ow of electrons.
As we have seen, this is exactly what a diode does.
RECTIFIER TESTING:
The following instructions can be used to test any bridge rectifer.
Use a DC continuity test light or a VOM (on the R x 100 scale) for all tests.
Disconnect all wires from the rectifer.
1
Connect test leads as shown in Figure A. If the meter beeps, the rectifer is
defective. If the meter does not beep, go to the next step.
2
Connect test leads as shown in Figure B. If the meter does not beep, the
rectifer is defective. If the meter beeps, go to the next step.
3
Connect test leads as shown in Figure C. If the meter beeps, the rectifer is
defective. If the meter does not beep, go to the next step.
4
Connect test leads as shown in Figure D. If the meter does not beep, the
rectifer is defective. If the meter beeps, go to the next step.
5
Connect test leads as shown in Figure E. If the meter beeps, the rectifer is
defective. If the meter does not beep, go to the next step.
6
Connect test leads as shown in Figure F. If the meter does not beep, the rectifer is defective. If the meter beeps, go to the next step.
7
Connect test leads as shown in Figure G. If the meter beeps, the rectifer is defective. If the meter does not beep, go to the next step.
8
Connect test leads as shown in Figure H. If the meter does not beep, the rectife r is defective. If the meter beeps, the rectifer is good.
OL
OL
0.000
FIG. A
0.000
FIG. E
-
DC
OL
FIG. B
OL
FIG. F
FIG. 1
AC
AC
0.000
FIG. C
0.000
FIG. G
+
DC
FIG. D
FIG. H