Graco FinishPro 390 Repair Electrical Manual page 13

Airless/air-assisted sprayer
Hide thumbs Also See for FinishPro 390:
Table of Contents

Advertisement

Step 1
110-120 AC
Cord plugged in.
Switch ON.
V
Wires connected
to control board.
- -
Meter on AC Volts
J4
J3
Control
Board
To
Power Cord
Step 3
Cord plugged in.
100 + DC
Switch ON.
Pressure Switch
Turned to high.
V
Meter on DC volts.
- -
Red
Yellow
Blk
Control
Board
FinishPro 390
261779
Control Board
Airless Motor will not run
Pressure
Control
Motor
Assembly
2X Yellow
White
Power
Plug
BEEP
� �
Yellow
Red
Blk
Red (+)
Black (-)
Replaceable Fuse
FUSE
Black
Green
Step 4
Checking the motor
thermistor switch .
Unplug the motor
wires from control
board.
Carefully insert the
meter probes into the
2 yellow wires.
Meter should read
continuity.
Note: motor should be
cooled down.
Step 2
110-120 AC
Cord plugged in.
Switch ON.
V
Wires connected
to control board.
- -
Meter on AC Volts
F1
Control
FUSE
Board
J4
ON/OFF
Switch
To Compressor
Step 5
Motor plugged in.
Cord plugged in.
Switch ON.
Pressure switch
unplugged.
Control
Board
Insulated Jumper wire
stripped on the ends
J1
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Finishpro 395

Table of Contents