Closing the device LED indications

When closing the devices the LED will flash as follows:-
Pink - trying to connect
Green - connected
Red - connection failed
When the device is closed and has succesfully connected to the system it will be in
walktest mode for 10 minutes.

1.5 Testing comissioning and LED indications

When installation is complete, the device should be thoroughly walk tested to
ensure the desired protection is being achieved, and any adjustments to the
device are made to cater for the specific location and any local site conditions.
Note: LED's are disabled during normal use. To enable the LED's put the panel into
walk test mode. Devices will be in walktest mode for 10 minutes after they have
been learnt to the system and the device has ben closed.
State
Warm up
Alarm
PIR only on D20-W/CD-W
MW only on D20-W/CD-W
Learning
Learning OK
Learning failed

Walk test

Walk test all devices to ensure you have adequate coverage, and that there are no
obstructions in the detection area.
D20-W & CD-W Microwave Range Adjustment
INS879EN-2 24/68
Colour
Flash 0.5s on 0.5s off
Flash fast
Momentary green
Momentary red
Flash