VII. Venting (continued)
Table 9: Recommended Venting Configurations and Material Options
Vent & Intake
Materials
Two Pipe
Stainless Steel vent,
Galvanized Steel or
PVC intake
Two Pipe
Polypropylene vent,
Galvanized Steel or
PVC intake
Two Pipe
CPVC vent,
Galvanized Steel or
PVC intake
Room air for
combustion;
SS, PP,
or CPVC vent
Notes:
1. It is recommended by the manufacturer to use tees for both intake and vent terminations.
2. All elbows being refereed to are 900 elbows.
3. All terminations shall have bird screens.
4. All non-metallic venting exposed to sunlight shall be UV resistant.
NOTICE
NOTICE
Vent
Penetration
Option
Through Structure
Intake
Horizontal Sidewall
1
Vent
Horizontal Sidewall
Intake
Horizontal Sidewall
2
Vent
Vertical Roof
Intake
Vertical Roof
3
Vent
Vertical Roof
Intake
Horizontal Sidewall
4
Vent
Horizontal Sidewall
Intake
Horizontal Sidewall
5
Vent
Vertical Roof
Intake
Vertical Roof
6
Vent
Vertical Roof
Intake
Horizontal Sidewall
7
Vent
Horizontal Sidewall
Intake
Horizontal Sidewall
8
Vent
Vertical Roof
Intake
Vertical Roof
9
Vent
Vertical Roof
10
Vent
Horizontal Sidewall
11
Vent
Vertical Roof
Use of cellular core PVC (ASTM F891), cellular core CPVC, or Radel®
(polyphenylsulfone) in non-metallic venting systems is prohibited.
Covering non-metallic vent pipe and fittings with thermal insulation is
prohibited.
Termination
Tee or elbow
Tee or straight
Tee or elbow
Tee or straight
Tee or 2 elbows
Tee or straight
Tee
Tee or straight
Tee
Tee or straight
Tee or 2 elbows
Tee or straight
Tee or elbow
Tee or straight
Tee or elbow
Tee or straight
Tee or 2 elbows
Tee or straight
Tee or straight
Tee or straight
22
Reference
Parts Table
Figure
Figure 8
Table 13
-
Figure 9
Figure 8
Table 14
-
Table 15
Figure 9
Figure 8
-
-
Figure 9
Table 13
-
Table 15