15. Troubleshooting

The table below contains a list of error symptoms and explains what you can do to solve the problem if your tool fails to
work properly. If the problem persists after working through the list, please contact your nearest service workshop.
Fault
Engine does not start
Generator has too little or no
voltage
The battery does not charge
up
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Cause
Oil pressure switch tripped red LED
No diesel fuel
Mechanical switch set to "STOP"
Diesel filter blocked
Air filter dirty
Diesel filter frozen due to low out
door temperature
The fuse is defective
Controller or capacitor defective
Overcurrent circuit-breaker has
tripped
Air filter dirty
The fuse is defective
Remedy
Check oil level, top up with engine oil
Top up with diesel fuel
Set mechanical switch to "RUN"
Clean or replace the diesel filter
Clean or replace the air filter
Proceed as described in the point entitled "Win-
ter operation"
Change the defective fuse
Contact your dealer
Reduce consumption
Clean or replace the filter
Change the defective fuse