Troubleshooting - TMC Aquarium V2 Auto Top Up Compact Manual

Hide thumbs Also See for V2 Auto Top Up Compact:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
TROUBLE SHOOTING
Problem: Pump not activating with low water.
1. Possible Cause: No power.
Solution: Check connections and ensure float switch and top up pump are connected to
the correct DC jacks.
2. Possible Cause: Float not moving with water level due to deposits or detritus on the
shaft/float.
Solution: Clean float and shaft ensuring they are free from deposits and detritus, which may
build up over time.
Problem: Pump constantly on.
1. Possible cause: Float in the float switch is stuck.
Solution: Clean float and shaft ensure they are free from deposits and detritus, which may
build up over time.
Problem: Pump activating with high water level.
1. Possible cause: Air bubbles trapped under the float
Solution: manually move float to free bubbles, ensure guard is correctly positioned and the
float is in an area free from collecting bubbles.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

95219522

Table of Contents