Argo X3 ECO PLUS User And Installation Manual

Argo X3 ECO PLUS User And Installation Manual

Mono split air conditioners – r32
Hide thumbs Also See for X3 ECO PLUS:

Advertisement

AIR CONDITIONERS – R32
USER and INSTALLATION MANUAL
INDOOR UNITS
X3I ECO PLUS 27 HL WF
X3I ECO PLUS 35 HL WF
X3I ECO PLUS 52 HL WF
X3I ECO PLUS 70 HL WF
Please read this manual carefully before installing and using the air conditioner, and
retain for future reference.
X3 ECO PLUS
MONO SPLIT
OUTDOOR UNITS
X3I ECO PLUS 27 SH
X3I ECO PLUS 35 SH
X3I ECO PLUS 52 SH
X3I ECO PLUS 70 SH
V 10/19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X3 ECO PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Argo X3 ECO PLUS

  • Page 1 X3 ECO PLUS MONO SPLIT AIR CONDITIONERS – R32 USER and INSTALLATION MANUAL INDOOR UNITS OUTDOOR UNITS X3I ECO PLUS 27 HL WF X3I ECO PLUS 27 SH X3I ECO PLUS 35 HL WF X3I ECO PLUS 35 SH X3I ECO PLUS 52 HL WF...
  • Page 2: Table Of Contents

    Contents Information for use The Refrigerant R32 Precautions for use Description of components Guide to the remote control and display Remote control buttons Getting to know the display icons Getting to know the remote control buttons Getting to know the button combination functions Operating guide Replacing the remote control batteries WiFi guide...
  • Page 3: Information For Use The Refrigerant R32

    INFORMATION FOR USE The Refrigerant R32 Appliance filled with flammable gas R32. Before using the appliance, read the owner’s manual. Before installing the appliance, read the installation manual. Before repairing the appliance, read the service manual.  To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The refrigerant is the fluoride R32 = GWP (Global warming potential).
  • Page 4: Precautions For Use

    INFORMATION FOR USE Precautions for use WARNING  This product is not a toy. Children of less than 3 years should be kept away unless continuously supervised.  This device is not intended for persons (including children aged from 8 years and above) with reduced physical, sensory or mental capabilities, or without the necessary experience and knowledge, unless they have received the necessary supervision or instruction concerning use of the appliance by a person responsible for their...
  • Page 5  The unit must be installed and serviced by a qualified technician. Otherwise, there is a risk of damage or personal injury.  Frequency band(s) in which the radio equipment operates 2400MHz-2483.5MHz.  Maximum radio-frequency power transmitted in the frequency band(s) in which the radio equipment operates: 20dBm.
  • Page 6: Description Of Components

    Description of components Indoor unit remote control ingresso aria air inlet pannellino panel filtro filter Tasto ausiliario auxiliary button Deflettore orizzontale horizontal flap uscitadell’aria air outlet Spia alimentazione power indicator Finestrella ricevitore receiver window Spia temperatura temperature indicator telecomando remote control Spia riscaldamento Heating indicator Spia raffreddamento...
  • Page 7: Guide To The Remote Control And Display Remote Control Buttons

    Outdoor unit Unitàesterna Outdoor unit ingresso aria air inlet impugnatura handle uscita aria air outlet GUIDE TO THE REMOTE CONTROL AND DISPLAY Remote control buttons V 10/19...
  • Page 8: Getting To Know The Display Icons

    Getting to know the display icons Getting to know the remote control buttons N.B.:  When you connect the power, the air conditioner will emit a beep. The power indicator will illuminate (red). You will now be able to control the air conditioner with the remote control. ...
  • Page 9 "FAN" button will allow you to adjust the fan speed. Pressing the "SWING" button will allow you to adjust the angle of airflow.  When you select cool mode, the air conditioner will run in cool mode. The  indicator will illuminate on the display.
  • Page 10 5. ▲/ ▼ button Press "▲" or "▼" once to increase or decrease the set temperature by 1°C. Press and hold "▲" or "▼" for 2 seconds to rapidly adjust the set temperature on the remote control. When set-up is complete, release the button and the indoor unit's temperature indicator will change accordingly.
  • Page 11 hour of unit operation, the temperature will decrease by 1°C and after two hours will decrease by 2°C. - SLEEP 2 the air conditioning operates on the basis of pre-set temperature curves. In cooling mode: 1. When the initial temperature is set to 16°C-23°C, after activating the Sleep function, the temperature will increase by 1°C every hour, after three hours the temperature will stabilize, after 7 hours the temperature will decrease by 1°C and the unit will start working constantly.
  • Page 12 10. TIMER ON / TIMER OFF button SETTING TIMER ON This function allows you to program the air conditioner to turn on. When you press this button, the icon will disappear from the display and the word "ON" will flash on the remote control display. Press "▲"...
  • Page 13: Getting To Know The Button Combination Functions

    13. Wi-Fi button Press this button to start the Wi-Fi function. When the Wi-Fi function is active, the "Wi-Fi" icon will appear on the remote control display. When the remote control is off, press and hold the "Mode" button and the "Wi-Fi" button simultaneously for 1 sec to return to the factory settings. 14.
  • Page 14: Operating Guide

    N.B.: • When the energy saving function is enabled, the fan will operate at the default automatic speed and cannot be adjusted. • When the energy saving function is enabled, the set temperature cannot be adjusted. The remote control will not send a signal to the unit when the TURBO button is pressed. ...
  • Page 15 N.B.:  When the unit is operating, point the remote control's signal transmitter at the indoor unit's receiver.  The distance between the transmitter and the receiver must not exceed 8 metres and should remain free of obstacles.  If the room contains a fluorescent light or cordless telephone, signal interference is likely to occur.
  • Page 16: Wifi Guide

    WIFI GUIDE How to set and operate the air conditioner with Wifi 1. Make sure that the device (smartphone or Tablet) used is equipped with a standard version of Android (version 4.4 or higher) and iOS (iOS7.0 or higher) as the operating system. For more details refer to the App.
  • Page 17 2. Registration and access. After installing the application, open "EWPE SMART" and click Sign up to register. PLEASE NOTE: • USERNAME: must be UNIQUE, composed of name + number, without spaces (eg Rossi57) • Personal email: if already registered, retrieve Username / Password. It is not possible to create another account with the same mail.
  • Page 18 In case of rensidential air conditioner: the fist box on left After choosing the category of interest, proceed with the reset of the unit. Different unit reset systems can be chosen depending on the type of unit / system and remote control (with or without wifi key).
  • Page 19 WIRE CONTROL OR REMOTE CONTROL WITH WIFI REMOTE CONTROL WITHOUT WIFI PORTABLE AIR BUTTON BUTTON (MODE and TURBO) CONDITIONER (CONTROL Direct the remote control towards Direct the remote control towards PANEL RESET) the unit. the unit. Press the button on the touch With the remote control off, press Press the "Mode"...
  • Page 20 After performing the electrical reset of the unit and entering the information, perform a search for the unit (Search appliance) and continue the configuration. Configuration of the main functions In the Homepage click on the device you wish to control and access the operating interface of it. 1.
  • Page 21 2. Temperature for each mode: just slide your finger on the indicated temperature 3. Ventilation speed for each mode: just slide your finger on the fan symbol (the adjustment possibilities vary depending on the mode) 4. Set advanced functions Click Function (Func) in the lower left corner of the interface to enter the advanced settings. V 10/19...
  • Page 22 X-FAN fucntion Vertical flap swinging Horizontal flap swinging (if available) Sleep function Light on indoor unit display Temperature unit conversion Swing setting Clic Up & down swing to turn the swing function on or off. Click the arrow in the lower right corner of the icon to go to the next screen and set the swing level.
  • Page 23 List of Preselections Clic Timer. Then clic + and make adjustments. Other functions 1. Homepage menu Click on the profile picture in the upper left corner of the homepage and set each menu function V 10/19...
  • Page 24 2. Group Control Click Group Control to use the present devices (Ex. Change the group name to "hhh" and set up the devices in the group list). When this group is working you can change the settings of the whole group. 3.
  • Page 25 4. Help Press Help to view the instructions for EWPE SMART APP 5. Feedback Clic Feedback to send a feedback on the product. 6. How to reset the air conditioner WiFi module: Turn off the unit with the remote control and disconnect the air conditioner power for at least 10 seconds.
  • Page 26: Emergency Operation

    Analysis of common network setting errors: If the short distance control does not work, perform the checks specified below: • Make sure the air conditioner power is connected. • Make sure that the air conditioner's WiFi function is normally active. •...
  • Page 27: Troubleshooting Possible Faults And Solutions

    Clean the filters Refit the filters • Use a vacuum cleaner to clean the filters. Refit the filters and close the front panel. • If they are very dirty, use water (below 45°C) and leave to dry in a cool, dark place. N.B.: ...
  • Page 28 Is there a fluorescent light in the room? Position the remote control next to the indoor unit. Turn off the fluorescent light and try again. Is the indoor unit's air inlet or outlet Remove the obstruction. blocked? In heat mode, has the indoor temperature Once the set temperature has been reached the set temperature? reached, the indoor unit will stop blowing...
  • Page 29: Analysing Faults And Solutions

    Analysing faults and solutions Error codes In the event of a fault, the temperature indicator on the indoor unit will flash to display the corresponding error code. Refer to the following list to identify the error code. Error code Faults and solutions Can be eliminated by turning the unit off and on again.
  • Page 30: Installation Instructions

    INSTALLATION INSTRUCTIONS Installation diagrams Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe V 10/19...
  • Page 31 INSTALLATION WARNINGS WARNING: Make sure that the power supply is disconnected before carrying out any work on the unit. WARNING: Wear appropriate personal protective equipment before carrying out any work on the unit. WARNING: The appliance must be reinstalled in accordance with national system regulations. WARNING: Wiring and installation must only be performed by a qualified technician trained to install, modify, extend and service the unit and perform safety and functionality tests.
  • Page 32: Choosing A Location For Installation

     Use the specified cable types for electrical connections between indoor and outdoor units. Securely lock the cables so that their terminals do not receive external stress.  Electric cables with insufficient capacity, incorrect cable connections and insecure cable terminals may cause electric shock or fire. Choosing a location for installation Essential requirements Indoor unit...
  • Page 33: Installation Indoor Unit Installation

    The unit is charged with a slightly inflammable refrigerant, R32. Improper handling of this gas may expose people and materials to serious damage. More details on this refrigerant are given at the beginning of this manual. Earthing 1. The air conditioner is a Class I appliance. The unit must be earthed with an appropriate device by a qualified technician.
  • Page 34 9000 12000 18000 24000 Drill a piping hole of diameter 55 or 70 at the chosen location for the outlet pipe. To allow for proper drainage, the piping hole in the wall must slant slightly downwards to the outdoor side, with a gradient of 5 –...
  • Page 35 Step five: connect the indoor unit pipe Position the pipe joint in the corresponding bellmouth. tubo giunto tubo dado raccordo Pre-tighten the union nut by hand. giunto pipe tubo joint dado union raccordo Adjust the torque according to the following table. Position the open-end spanner on the pipe joint position the torque wrench on the union nut.
  • Page 36 Step seven: connect the indoor unit electrical cable 1. Open the panel. Remove the screw that vite pannello secures the small panel covering the terminal board. coperchio cablaggio 2. Insert the indoor and outdoor unit connecting cable into the rear hole corresponding to the foro di passaggio cavo...
  • Page 37: Outdoor Unit Installation

    unità interna indoor unit cavo di alimentazione interno indoor and outdoor power cable ed esterno 3. Bind them evenly. tubo gas gas pipe 4. The liquid pipe and gas pipe must be bound fascetta binding tape separately at the end. tubo di scarico drain pipe tubo del liquido...
  • Page 38 Installation diagram and technical spaces The installation should be performed by qualified service personnel and experienced, reliably and in compliance with this manual. Contact your service centre prior to installation to prevent malfunction due to a unprofessional installation. In taking and moving the units it is necessary to be guided by qualified and experienced people.
  • Page 39: Vacuum Pump

    Vacuum pump Humid air left inside the refrigerant circuit can cause com- pressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump. (1) Unscrew and remove the caps from the 2-way and 3- way valves.
  • Page 40: Testing And Operation Functional Testing

    Have the piping and electrical wiring been installed Risk of malfunction or damage to components. correctly? Has the unit been properly earthed? Risk of electric leakage. Does the power cable meet requirements? Risk of malfunction or damage to components. Are there any obstructions at the air inlet or outlet? The cooling (heating) capacity may be insufficient.
  • Page 41: Safety Operation Of Flammable Refrigerant

    V 10/19...
  • Page 42: Procedure For Extending The Piping

    Procedure for extending the piping N.B.: Improper extension of piping is the main cause of refrigerant leaks. Proceed as shown below: 1. Cut the pipe 5. Expand the port • Check the length of the pipe based on the Expand the port using a pipe expander. distance between the indoor unit and outdoor unit.
  • Page 43 REGULATION (EU) No. 517/2014 - F-GAS The unit contains R32, a fluorinated greenhouse gas with global warming potential (GWP) = 675. Do not release R32 into the atmosphere. X3I ECO PLUS 27 SH Kg. 0,55 = 0,371 Tonn CO equiv. X3I ECO PLUS 35 SH Kg.

This manual is also suitable for:

X3i eco plus 27 hl wfX3i eco plus 35 hl wfX3i eco plus 52 hl wfX3i eco plus 70 hl wfX3i eco plus 27 shX3i eco plus 35 sh ... Show all

Table of Contents