Multi split air conditioners – r32 - wifi (25 pages)
Summary of Contents for Argo X3I ECO PLUS27 SH LH
Page 1
INDOOR UNIT OUTDOOR UNIT OUTDOOR UNIT X3I ECO PLUS 27 HL WF X3I ECO PLUS27 SH LH X3I ECO PLUS 35 HL WF X3I ECO PLUS35 SH LH Please read this manual carefully before installing and using the air conditioner, and...
Contents Information for use The Refrigerant R32 Precautions for use Description of components Guide to the remote control and display Remote control buttons Getting to know the display icons Getting to know the remote control buttons Getting to know the button combination functions Operating guide Replacing the remote control batteries WiFi guide...
INFORMATION FOR USE The Refrigerant R32 Appliance filled with flammable gas R32. Before using the appliance, read the owner’s manual. Before installing the appliance, read the installation manual. Before repairing the appliance, read the service manual. To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The refrigerant is the fluoride R32 = GWP (Global warming potential).
Page 4
DISCLAIMER CLAUSES The manufacturer assumes no responsibility for personal injury or loss of product characteristics caused (after appropriate verification) by: 1. Improper use of the product; 2. Modifications to the product made with equipment other than those indicated in the manufacturer's instruction manual 3.
INFORMATION FOR USE Precautions for use WARNING This product is not a toy. Children of less than 3 years should be kept away unless continuously supervised. This device is not intended for persons (including children aged from 8 years and above) with reduced physical, sensory or mental capabilities, or without the necessary experience and knowledge, unless they have received the necessary supervision or instruction concerning use of the appliance by a person...
Page 6
Otherwise, there is a risk of damage or personal injury. The air conditioner must be properly earthed. Improper earthing can cause electrical shock. Always install a circuit breaker. Otherwise, a fault may occur. The unit must be installed and serviced by a qualified technician. Otherwise, there is a risk of damage or personal injury.
Heating mode: from -22°C to +24°C (outdoor temperature) °C to +24°C (outdoor temperature) Description of components Description of components Indoor unit remote control DISPLAY Outdoor unit...
Getting to know the remote control buttons N.B.: When you connect the power, the air conditioner will emit a beep. The power indicator will illuminate (red). You will now be able to control the air conditioner with the remote control. ...
Page 10
When you select cool mode, the air conditioner will run in cool mode. The When you select cool mode, the air conditioner will run in cool mode. The indicator will When you select cool mode, the air conditioner will run in cool mode. The illuminate on the display.
Page 11
When setting the TIMER ON, TIMER OFF or CLOCK, press " When setting the TIMER ON, TIMER OFF or CLOCK, press "▲" or "▼" to adjust the time. ▲" or "▼" to adjust the time. (Please refer to the relevant sections for the CLOCK, TIMER ON and TIMER OFF buttons). (Please refer to the relevant sections for the CLOCK, TIMER ON and TIMER OFF buttons).
Page 12
1. When the initial temperature is set to 16°C-23°C, after activating the Sleep function, the temperature will increase by 1°C every hour, after three hours the temperature will stabilize, after 7 hours the temperature will decrease by 1°C and the unit will start working constantly. 2.
Page 13
This function allows you to program the air conditioner to turn on. When you press this button, the icon will disappear from the display and the word "ON" will flash on the remote control display. Press "▲" or "▼" to adjust the TIMER ON setting. Press and hold "▲"...
14. LIGHT button Press this button to turn off the indoor unit's display light. The icon will disappear from the remote control display. Press this button again to turn on the display light. The icon will appear on the display. 15.
The SLEEP and energy saving functions cannot operate simultaneously. If the energy saving function was set in cool mode, press the SLEEP button to cancel it. If the SLEEP function was set in cool mode, start the energy saving function to cancel it. 8°C heating function In cool mode, press the TEMP and CLOCK buttons simultaneously to start or stop the 8°C heating function.
The distance between the transmitter and the receiver must not exceed 8 metres and should remain free of obstacles. If the room contains a fluorescent light or cordless telephone, signal interference is likely to occur. When the remote control is not used for a month or more, remove the batteries. ...
Page 17
download and install the application. Install the App by referring to its guide. Once the installation is complete, the icon appears on the smartphone's home page. 2. After installing the application, open "EWPE SMART" and click Sign up to register: Please use as your account a name not common, adding for instance some numbers.
Page 18
In addition to accessing from the quick interface, you can also access the homepage by clicking on the profile image in the upper left corner. 4. Adding units Press + in the upper right corner of the homepage to add a unit.After choosing "AC", you can choose different unit reset systems depending on the type of system.
Page 19
TOUCHCONTROL PANEL REMOTE CONTROL WITH WIFI BUTTON REMOTE CONTROL WITHOUT WIFI BUTTON Press the button on the touch panel. Direct the remote control towards the unit. (MODE and TURBO) With the unit off, press and hold the "Wifi" With the remote control off, press the Direct the remote control towards the unit.
Page 20
Configuration of the main functions In the Homepage click on the device you wish to control and access the operating interface of it. 1. Select, operating mode, temperature and fan speed. V 04/20...
Page 21
2. Set advanced functions Click Function (Func) in the lower left corner of the interface to enter the advanced settings. V 04/20...
Page 22
Swing setting Clic Up & down swing to turn the swing function on or off. Click the arrow in the lower right corner of the icon to go to the next screen and set the swing level. List of Preselections Clic Timer.
Page 23
function. 2. Group Control Click Group Control to use the present devices (Ex. Change the group name to "hhh" and set up the devices in the group list). When this group is working you can change the settings of the whole group.
Page 24
Help Press Help to view the instructions forEWPE SMART APP. 5. Feedback Clic Feedback to send a feedback on the product. 6. How to reset the air conditioner WiFi module: V 04/20...
Turn off the unit with the remote control and disconnect the air conditioner power for at least 10 seconds. Reconnect the power supply. After 1 minute, press the "WiFi" and "Mode" buttons simultaneously. If the air conditioner beeps, it means that the WiFi module has been reset correctly. Attention: The configuration is carried out within 2 minutes.
MAINTENANCE Care and cleaning N.B.: Disconnect the power before servicing or cleaning the unit. Cleaning the casing of the indoor unit Use a soft, damp cloth to clean the outer surface of the unit. Do not use water that is too hot, solvents, petrol or other aggressive chemical compounds, talcum powder or brushes.
3. Check that the outdoor unit's support bracket is not damaged or corroded. If it is, contact the service centre. N.B. 4. Many packaging materials are recyclable materials. Please dispose of them in the appropriate recycling unit. 5. If you want to remove the air conditioner, please contact your local dealer or local service provider for the correct disposal method.
Fault Check Solution Is the unit operating in automatic mode? The temperature cannot be adjusted in The set automatic mode. Change the operating mode if you want to adjust the temperature cannot be temperature. adjusted Does the desired temperature fall outside The available temperature range is: 16 –...
Page 29
The circuit breaker keeps tripping. The air conditioner emits a burning smell. The indoor unit is leaking. Do not attempt to repair or reinstall the air conditioner yourself. If the air conditioner is operated in abnormal conditions, malfunction, electric shock or fire may result.
INSTALLATION INSTRUCTIONS Installation diagrams Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe V 04/20...
Page 31
INSTALLATION WARNINGS WARNING: Make sure that the power supply is disconnected before carrying out any work on the unit. WARNING: Wear appropriate personal protective equipment before carrying out any work on the unit. WARNING: The appliance must be reinstalled in accordance with national system regulations. WARNING: Wiring and installation must only be performed by a qualified technician trained to install, modify, extend and service the unit and perform safety and functionality tests.
Use the specified cable types for electrical connections between indoor and outdoor units. Securely lock the cables so that their terminals do not receive external stress. Electric cables with insufficient capacity, incorrect cable connections and insecure cable terminals may cause electric shock or fire. Choosing a location for installation Essential requirements Indoor unit...
Page 33
9. The unit must be installed in accordance with national wiring regulations. 10. Installation must only be performed by trained individuals in accordance with regulations. The unit is charged with a slightly inflammable refrigerant, R32. Improper handling of this gas may expose people and materials to serious damage. More details on this refrigerant are given at the beginning of this manual.
INSTALLATION Indoor unit installation Step one: choose of indoor unit position Decide where to install the unit based on room design, architectural limitations and customer requirements. Check that in the selected location the unit can be accessed for servicing and cleaning the filters.
Page 35
Interno Indoors Outdoors Step four: outlet pipe Once you have selected the direction of the The pipe can be brought out in various different outlet (left or right), drill the corresponding directions: right, rear right, left or rear left. hole at the bottom. destra right destra...
Page 36
Wrap the indoor pipe and the joint of the connecting pipe with an insulating tube. Then wrap with tape. Step six: install the condensate drain pipe Connect the drain pipe to the outlet pipe of the indoor unit. Bind the joint with tape. tuboisolante insulating tube tubo di uscita...
Page 37
blue nero black marrone brown giallo-verde yellow-green collegamentounitàesterna Outdoor unit connection 4. Reposition the terminal block cover and tighten the screws. 5. Close the panel. N.B.: • All wiring must be connected as shown on the unit's wiring diagram. All indoor and outdoor unit cables must be connected by a qualified technician. •...
interno indoors esterno outdoors tubo a parete wall pipe gomma di sigillatura rubber sealant ganciosuperiore upper hook gancio inferiore del telaio di montaggio a parete lower hook of wall-installation frame N.B.Avoid bending the drain pipe too much in order to prevent clogging. Outdoor unit installation For all connections refer to the wiring diagrams supplied with the unit.
Page 39
Collocation Install junction and drain hose (only for models with heat pump) Use bolts to secure the unit to the floor, When the unit is in heating mode it produces which must be a solid ground. When condensation, which flows from the outdoor unit. installing the unit on the wall or on the In order not to disturb neighbors and to respect roof, make sure the support is firmly...
Page 40
Outdoor unit installation Step one: secure the outdoor unit support 1. Choose a location for the unit according to the structure of the house. 2. Use expansion screws to secure the outdoor unit support in the chosen position. N.B.: • Take the appropriate safety measures when installing the outdoor unit.
Page 41
pipe. Hex nut diameter Tightening torque (Nm) 15 – 20 6.35 30 – 40 9.52 45 – 55 12.7 60 – 65 15.88 valvola del liquido liquid valve tubo del liquido liquid pipe tubo del gas gas pipe valvola del gas gas valve Step five: connect the outdoor electrical cable 1.
Il tubo di scarico non deve salire The drain pipe must not go verso l’alto upwards • To ensure uniform drainage, the water outlet must not be placed in water. Il tubo di scarico non deve The drain pipe must not be ondeggiare twisted Il tubo di scarico non deve...
Maintenance Only use adequate equipment for the R32 refrigerant Do not use a different refrigerant from R32. Do not use mineral oils to clean the unit. Post-installation checks Checks Possible fault Has the unit been installed securely? The unit could fall, move or produce excessive noise.
Page 44
connecting tube height length difference 9000 Btu/h 12000 Btu/h 18000Btu/h 24000Btu/h Warning! Note the additional charge on the data plate affixed to the outdoor unit. Additional oil and refrigerant charging If the length of the connecting pipe is increased by 10 m compared to the standard length, add 5 ml of refrigeration oil for every 5 m of pipe added.
Procedure for extending the piping N.B.: Improper extension of piping is the main cause of refrigerant leaks. Proceed as shown below: 1. Cut the pipe 5. Expand the port • Check the length of the pipe based on the Expand the port using a pipe expander. distance between the indoor unit and outdoor unit.
Page 47
REGULATION (EU) No. 517/2014 - F-GAS The unit contains R32, a fluorinated greenhouse gas with global warming potential (GWP) = 675. Do not release R32 into the atmosphere. X3I ECO PLUS 27 SH HL Kg. 0,55 = 0,371Tonn CO equiv. X3I ECO PLUS 35 SH HL Kg.
Need help?
Do you have a question about the X3I ECO PLUS27 SH LH and is the answer not in the manual?
Questions and answers