AIR CONDITIONERS MONOSPLIT R32 WIFI USER and INSTALLATION MANUAL INDOOR UNIT OURDOOR UNIT X3I ECO PLUS 27 HL WF X3I ECO PLUS 27 SH X3I ECO PLUS 35 HL WF X3I ECO PLUS 35 SH X3I ECO PLUS 52 HL WF...
Contents Information for use The Refrigerant Precautions for use Description of components Guide to the remote control and display Remote control button and display icons Getting to know the remote control buttons Getting to know the button combination functions Replacing the remote control batteries WiFi Guide Google Home Instruction Emergency operation...
Page 3
This product is not intended for use by persons (including children) with reduced physical, sensory or mental abilities or who do not possess adequate experience and knowledge, unless they are supervised or instructed in the use of the product. by a person responsible for their safety. Children must be supervised to ensure that they do not play with the appliance.
Page 4
Explanation of symbols This symbol indicates the possibility of death or serious injury. WARNING This symbol indicates the possibility of injury or damage to CAUTION property. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage. Indicates a hazard generally marked with the word WARNING or CAUTION.
Appliance filled with flammable gas R32. Before using the appliance, read the owner’s manual. Before installing the appliance, read the installation manual. Before repairing the appliance, read the service manual. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The •...
INFORMATION FOR USE Precautions for use WARNING • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Page 7
• Do not spill water on the remote controller, otherwise the remote controller may be broken. • When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service. •...
Page 8
• Unstable power supply or incorrect wiring may result in electric shock, fire hazard or malfunction. Please install proper power supply cables before using the air conditioner. • Correctly connect the phase, neutral and ground wires of the power outlet. •...
Page 9
• Bear in mind that the appliance is filled with flammable gas R32. Improper handling of the device creates the risk of serious injury to persons and damage to materials. Details of this refrigerant can be found in the "refrigerant" chapter. •...
Description of components Indoor unit The display may vary from the graphic above. Please refer to the purchased product for the actual display content and positions). Outdoor unit...
GUIDE TO THE REMOTE CONTROL AND DISPLAY Remote control buttons and display icons Getting to know the remote control buttons When you connect the power, the air conditioner will emit a beep. The power indicator will illuminate (red). You will now be able to control the air conditioner with the remote control. •...
Page 12
ON/OFF button Press the ON/OFF button to turn the air conditioner on or off. When you turn on the air conditioner, the power indicator on the indoor unit's display will illuminate (green). The colour varies for different models. The indoor unit will emit a beep.
Page 13
If the X-FAN function is not selected, when the air conditioner is switched off by pressing the ON / OFF button, the fan goes off together with the unit. TURBO button In cool/heat mode, press this button to switch to rapid cool/heat mode. The icon will appear on the remote control display.
Page 14
N.B.: • may not be available. When the air conditioner receives this signal, the fan will start operating in automatic mode SLEEP button By pressing this button you can select Sleep 1 , Sleep 2 , Sleep 3 and cancel the Sleep function. - SLEEP 1 works in cooling and dehumidification mode: after one hour of unit operation, the temperature will increase by 1°C, after 2 hours it will increase by 2°C;...
Page 15
then adjust its operation automatically based on the difference between the detected temperature and the set temperature. Press the button again to exit the I FEEL function. The icon will disappear from the display. The remote control should be positioned near the user when this function is selected. The remote control should not be placed anywhere high or low temperatures may occur to avoid inaccurate ambient temperature detection.
5. In auto mode the internal fan operates in auto quiet mode according to the current modes: cooling, heating and ventilation. Wi-Fi button Press this button to start the Wi-Fi function. When the Wi-Fi function is active, the "Wi-Fi" icon will appear on the remote control display.
Page 17
Autoclean function With the unit off, press and hold the MODE and FAN buttons simultaneously for 5 seconds to activate or deactivate the automatic cleaning function. When the automatic cleaning function is activated, the indoor unit displays "CL". The function will see condensation, ice formation, defrosting and drying phases take place in sequence aimed at eliminating all residues of dust and pollutants and any trace of condensation from the evaporator.
Operating guide 1. When you connect the power, press the "ON/OFF" button on the remote control to turn the air conditioner 2. Press the MODE button to select the desired operating mode: AUTO, COOL, DRY, FAN or HEAT. 3. Press "▲" or "▼" to adjust the desired temperature. (The temperature cannot be adjusted in automatic mode.) 4.
WIFI GUIDE The air conditioner must be in constant connection with a wireless router or access point connected to the internet. Mobile devices such as smartphones and tablets, on which dedicated applications are installed and the Wi-Fi modules subsequently configured, can be used as remote controls once connected to the internet. How to set up and operate the air conditioner with Wifi 1.
Page 20
Open the app Make the registration before Access 3. Adding units Clicking on the icon of the little man opens a menu that includes, among other things, the "Help" function. Follow the instructions that appear on your device to add the unit. or add a new unit, press + in the upper right corner of the homepage.
Page 21
A menu appears with all the categories of devices that can be connected. Select the relevant type: In case of residential air conditioner: the first box on left: After choosing the category of interest, proceed with the reset of the unit. Different unit reset systems can be chosen depending on the type of unit / system and remote control (with or without wifi key).
Page 22
WIRE CONTROL OR PORTABLE REMOTE CONTROL WITH WIFI REMOTE CONTROL WITHOUT AIR CONDITIONER (CONTROL BUTTON WIFI BUTTON (MODE and PANEL RESET) Direct the remote control towards TURBO) Press the button on the touch panel. Direct the remote control towards the unit. With the unit off, press and hold the unit.
Page 23
After performing the electrical reset of the unit and entering the information, perform a search for the unit (Search appliance) and continue the configuration. Configuration of the main functions In the Homepage click on the device you wish to control and access the operating interface of it. 1.
Page 24
Ventilation speed for each mode: just slide your finger on the fan symbol (the adjustment possibilities vary depending on the mode) 2. Set advanced functions Click Function (Func) in the lower left corner of the interface to enter the advanced settings. X-FAN function Vertical flap swinging Horizontal flap swinging...
Page 25
Sleep function Light on indoor unit display Temperature unit conversion Swing setting Clic Up & down swing to turn the swing function on or off. Click the arrow in the lower right corner of the icon to go to the next screen and set the swing level. List of Preselections Clic Timer.
Page 26
Other functions 1. Homepage menu Click on the profile picture in the upper left corner of the homepage and set each menu function. 2. Group Control Click Group Control to use the present devices (Ex. Change the group name to "hhh" and set up the devices in the group list).
Page 27
3. Home Management Click Home Management to create or manage a "family system". You can add new members to the family system of the registered account.
Page 28
4. Help EWPE SMART APP. Press Help to view the instructions for 5. Feedback Clic Feedback to send a feedback on the product. 6. How to reset the air conditioner WiFi module: Turn off the unit with the remote control and disconnect the air conditioner power for at least 10 seconds. Reconnect the power supply.
Google Home Instruction 1. Premise Before using Google Home to control intelligent equipment, please make sure you have satisfied the following conditions. Your mobile phone has installed the latest version of Google Home app or Google app (for Android only) ...
Page 30
Confirm to add Google Home device and click “Yes”. It will give out a sound to confirm that you have connected to the right device. After hearing the sound, click “Yes” to enter the next step.
Page 31
Join in Help Improve Google Home and click “Yes, I’m in” or “No thanks”. Distinguish the room of Google Home from the other Google device areas, click “NEXT”, revise room name and click “Continue”.
Page 32
Then select Wi-Fi network and click “NEXT” to wait for device network connection. Set Google Home and click “More”. Click “I AGREE”.
Page 33
According to the prompting, choose if you agree the corresponding operation, if it displays “Google Home is ready”, choose “Continue” to the next step. Here comes the language control guidance course, after listening, click “Finish setup”, then Google Home setting is completed.
Page 34
4. Add EWPE app account In Google Home App homepage, click “+” button. Click “Set up device”.
Page 35
Select Works with Google. Search “Ewpe SmartHome”. Search Ewpe SmartHome on the list and click it, choose the country where your Ewpe Smart App account is, input EWPE App account and password and click “Ewpe SmartHome” to add it.
After adding, your device will appear on the device list. 5. Use Google Home to control your intelligent device Now, you can use Google Home to control your intelligent device. Take Air Conditioning as an example, the supporting instruction includes: Ok Google, turn on/off Air Conditioning.
MAINTENANCE Care and cleaning N.B.: Disconnect the power before servicing or cleaning the unit. Cleaning the casing of the indoor unit Use a soft, damp cloth to clean the outer surface of the unit. Do not use water that is too hot, solvents, petrol or other aggressive chemical compounds, talcum powder or brushes.
After-use checks 1. Disconnect the power supply. 2. Clean the indoor unit's panel and filters. 3. Check that the outdoor unit's support bracket is not damaged or corroded. If it is, contact the service centre. N.B. 1. Many packaging materials are recyclable materials. Please dispose of them in the appropriate recycling unit.
Page 39
Was the unit restarted immediately after Wait 3 minutes and then restart the unit. shutdown? Is the setting on the remote control correct? Reset the function. The indoor unit's Is the indoor temperature and humidity high? Indoor air cools rapidly. Wait for the air outlet indoor temperature and humidity to fall produces a mist...
Analysing faults and solutions Error codes In the event of a fault, the temperature indicator on the indoor unit will flash to display the corresponding error code. Refer to the following list to identify the error code. Error code Faults and solutions Can be eliminated by turning the unit off and on again.
INSTALLATION WARNINGS WARNING: Make sure that the power supply is disconnected before carrying out any work on the unit. WARNING: Wear appropriate personal protective equipment before carrying out any work on the unit. WARNING: The appliance must be reinstalled in accordance with national system regulations.
Electrical connection requirements Safety precautions 1. Electrical safety standards must be met when installing the unit. 2. Use a power supply circuit and circuit breaker that comply with local safety regulations. 3. Make sure that the power supply matches the requirements of the air conditioner. An unstable power supply or incorrect wiring may result in a fault.
INSTALLATION Indoor unit installation Step one: choose of the position Decide where to install the unit based on room design, architectural limitations and customer requirements. Check that in the selected location the unit can be accessed for servicing and cleaning the filters. To install, use the installation plate as a template to identify the exact position for the wall plugs and through-hole in the wall.
Page 45
Step four: outlet pipe Once you have selected the direction of the The pipe can be brought out in various different outlet (left or right), drill the corresponding hole directions: right, rear right, left or rear left. at the bottom. Step five: connect the indoor unit pipe 1.
Page 46
Step six: install the condensate drain pipe 1. Connect the drain pipe to the outlet pipe of the indoor unit. 2. Bind the joint with tape. N.B.: • Add an insulating tube to the indoor drain pipe to prevent condensation. •...
Page 47
4. Reposition the terminal block cover and tighten the screws. 5. Close the panel. N.B.: • All wiring must be connected as shown on the unit's wiring diagram. All indoor and outdoor unit cables must be connected by a qualified technician. •...
N.B.: • Avoid bending the drain pipe too much in order to prevent clogging. Outdoor unit installation Step one: secure the outdoor unit support 1. Choose a location for the unit according to the structure of the house. 2. Use expansion screws to secure the outdoor unit support in the chosen position. N.B.: •...
Page 49
Step two: install the drain joint Step three: secure the outdoor unit 1. Connect the outdoor drain joint into the hole 1. Position the outdoor unit on the support. on the chassis, as shown below. 2. Secure the foot holes of the outdoor unit with 2.
Page 50
Step five: connect the outdoor electrical cable 1. Remove the wire clip. Connect the power cable and the signal control cable (only for cooling and heating units) to the wiring terminal according to colour. Secure them with the screws. 2. Secure the power cable and the signal control cable with the clip (only for cooling and heating units). N.B.: •...
Page 51
Vacuum pump Using the vacuum pump • Remove the valve caps of the liquid valve and gas valve and remove the nut of the refrigerant charge port. • Connect the piezometer charge pipe to the refrigerant charge bore of the gas valve. Then connect the other charge pipe to the vacuum pump.
• Remove the piezometer. Fully open the plunger of the liquid valve and gas valve with the inner hex key. • Tighten the screw caps of the valves and refrigerant charge port. • Reinstall the handle. Leak detection Check for leaks using a leak detector. If you do not have a leak detector you can use soapy water. Post-installation checks Checks Possible fault...
APPENDICES Piping configuration 1. Standard connecting tube length:5 m. 2. Minimum connecting tube length: 3 m. 3. Maximum connecting tube length and maximum height difference: Maximum Maximum Capacity connecting tube height length difference 9000 Btu/h 12000 Btu/h 18000Btu/h 24000Btu/h Warning! Note the additional charge on the data plate affixed to the outdoor unit. Additional oil and refrigerant charging •...
Page 54
• The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area is shown on the following “table a”. • Leak test is mandatory after installation. table a - Minimum room area ( m ) Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1 2.2...
Procedure for extending the piping N.B.: Improper extension of piping is the main cause of refrigerant leaks. Proceed as shown below: 1. Cut the pipe 5. Expand the port • Check the length of the pipe based on the Expand the port using a pipe expander. distance between the indoor unit and outdoor unit.
Warnings for the refrigeration system specialist Here are warnings and safety instructions for the maintenance of systems containing flammable refrigerant (repairs should only be carried out by specialists). a) Any person involved in the work or in the interruption of a refrigeration circuit must be equipped with PEF (European Refrigerators License) as required by the D.P.R.
Page 57
If hot work is to be performed on the refrigeration equipment or any associated part, adequate fire fighting equipment must be available. It is necessary to have a dry powder or CO2 extinguisher adjacent to the charging area. g) Ventilated area Make sure the area is outdoors or is adequately ventilated before breaking into the system or performing any hot work.
Page 58
• Recovery equipment and cylinders comply with appropriate standards. D. If possible, drain the refrigerant system. E. If vacuum is not possible, make a manifold so that the refrigerant can be removed from the various parts of the system. F. Make sure the cylinder is placed on the scale before recovery takes place. G.
Page 59
For appliances containing flammable refrigerants, the system must be flushed with OFN to make the unit safe. You may need to repeat this process several times. Compressed air or oxygen must not be used for purging refrigerant systems. For appliances containing flammable refrigerants, flushing must be achieved by breaking the vacuum in the system with OFN and continuing to fill until the operating pressure is reached, then discharging to the atmosphere and finally lowering the vacuum.
Page 60
The unit contains R32, a fluorinated greenhouse gas with global warming potential (GWP) = 675. Do not release R32 into the atmosphere. X3I ECO PLUS 27 SH - Kg. 0,53 = 0,357 Tonn CO equiv. X3I ECO PLUS 35 SH - Kg. 0,57 = 0,384 Tonn CO equiv.