5.6

Securing the burner to the boiler

Provide an adequate lifting system of the burner.
To install the burner on the boiler, do the following:
 insert the screw and two nuts 9) on the flange 1), (see
Fig. 9).
 If necessary, widen the holes of the insulating gasket
4) Fig. 7).
 Fix the flange 1) to the boiler door 3) using the screws 5) and
(if necessary) the nuts 2) interposing the insulating gasket 4)
(Fig. 10).
 Open the boiler door and insert the choke 9) on the recircu-
lating pipe 6), adjusting it according to the calibrations in
Tab. H, on page 22;
 Insert the recirculating pipe 6) on the blast tube of the burner
7), and fix it with the nut 8)(Fig. 10).
NOTE:
when the installation is complete, check the burner is slight-
ly tilted, as shown in Fig. 8.
In any event, make sure that the combustion head
crosses the entire thickness of the boiler door and
it should be a maximum of 180 mm.
WARNING
Refractory lining included.
The seal between burner and boiler must be
airtight.
WARNING
6