Ordering information
Abbrev.
column
Example:
Product
VPB............ = VPB
Line
40........................... = 40
Series
4........................................ = 4
Control panel interface
CDI....................................... = D1
CDI+ .................................... = D2
PC box
2 slots, 2 x PCI........................... = L
4 slots, 4 x PCI........................... = M
2 slots, 1 x PCI + 1 x PCIe......... = N
2 slots, 2 x PCIe......................... = P
4 slots, 2 x PCI + 2 x PCIe......... = Q
4 slots, 4 x PCIe......................... = R
Memory capacity (RAM)
8 GB.................................................. = 8G0
16 GB................................................ = 16G
Interface
Without special interface........................... = NN
System configuration
Celeron C3955U, 2,00 GHz................................... = C4
Core i5-6300U, 2,40 GHz...................................... = D7
Core i7-6820EQ, 2,80 GHz.................................... = D8
Connecting voltage
DC 24 V......................................................................... = D
Hard disk (HD)
2,5", min. 320 GB................................................................ = D
2,5", min. 320 GB (2 x HDD in Raid 1)................................ = E
2,5", min. 192 GB, Solid State Disk (SSD).......................... = H
2,5", min. 192 GB (2 x SSD in Raid 1)................................ = K
2,5", min. 192 GB (2 x SSD) .............................................. = M
Drive
Without.................................................................................... = N
Other design
Without.............................................................................................. = NN
Firmware and Software
Denotes that firmware and software must be ordered as
separate subposition................................................................................ = FW
Note:
1) Memory capacity „8G0" is only available with system configuration „C4" and „D7"
Memory capacity „16G" is only available with system configuration „D8"
By the memory capacity it is a minimum disclosure
2) Hard disk (HD) „E" is only available with system configuration „D7" and „D8"
Harddisk (HD) „K" is only available with system configuration „D7" and „D8"
Fig. 15-1: Type code of the control cabinet PC IndraControl VPB 40.4