IndraControl VPB 40.4
Observe the following when mounting the shield connection:
1. Only remove the CDI cable jacket on the length required for the
connection.
The CDI cable is sensitive to mechanical load where the jacket was
removed. Ensure that the CDI cable shielding is not damaged when
removing the cable jacket.
Fig. 10-17: CDI cable with RJ45 plug
Fig. 10-18: CDI cable with partially removed jacket
2. Remove the foil shield.
CDI cables are equipped with an additional foil shield. The foil shield
must not be used for the connection. The foil shield is usually
plastic-coated on one side for an improved stability. The plastic
coating is insulating.
Fig. 10-19: Foil shield of the CDI cable
Mounting, demounting and electric installation
R911376309_Edition 02 Bosch Rexroth AG
39/57