baltur TBG 80 LX PN V Manual User Instructions page 32

Two-stage progressive / modulating gas burners with inverter
Hide thumbs Also See for TBG 80 LX PN V:
Table of Contents

Advertisement

Available languages

Available languages

TECHNICAL SPECIFICATIONS
HEATING CAPACITY
OPERATION
NOx EMISSIONS
FAN MOTOR
ABSORBED ELECTRICAL POWER*
line FUSE
IGNITION TRANSFORMER
VOLTAGE
PROTECTION RATING
FLAME DETECTOR
NOISE**
AMBIENT TEMPERATURE OF OPERATION
WEIGHT
Natural Gas (G 20)
FLOW RATE
PRESSURE
STANDARD ACCESSORIES
BURNER COUPLING FLANGE
INSULATING GASKET
STUD BOLTS
HEXAGONAL NUTS
FLAT WASHERS
*)
Total absorption at start with ignition transformer on and fan motor supplied at 50 Hz.
**) Sound pressure level measured in the laboratory of the manufacturer with burner running on test boiler, at maximum rated heating capacity.
TECHNICAL AND FUNCTIONAL SPECIFICATIONS
• Two-stage progressive/modulating output operation.
• Gas adjustment through the proportional working valve
controlled pneumatically.
• Combustion head with partial recycling of exhaust gases at
low NOx emissions (TBG 85 PN-V Class II), (TBG 80 LX PN-V
Class III).
• High fan output, low electrical absorption, low noise.
• Ambidextrous hinge opening for easy access to the combustion
head when burner is installed.
• Airflow adjustment with linear opening gate driven by an electric
servomotor.
TBG 85 PN V
850
MAX kW
170
MIN kW
Modulating / Progressive two stage burner
< 120 (Class II according to
mg/kWh
EN 676)
kW
r.p.m.
kW
230 V
26 kV - 40 mA - 230/240 V - 50/60 Hz
1N ~ 230 V + 10% - 15% - 50/60 Hz
dBA
MAX
° C
MIN
° C
kg
85.5
MAX
m³n/h
17
MIN
m³n/h
360
MAX
mbar
TBG 85 PN V
• Adjustment of the number of revolutions of the fan when the
requests by the burner vary through a frequency converter
to obtain a noticeable reduction in noise and electricity
consumption.
• Closing of air gate in pause.
• Control panel prepared for connection by plugs/sockets
(supplied) with 4 and 7 poles.
• Control panel with protection rating IP55.
• Sliding coupling flange to the generator, to adapt the
protuberance of the head to various types of heating generators.
• Gas train exit possibility at the top or at the bottom.
4 / 26
0006081534_201512
TBG 80 LX PN V
800
130
< 80 (Class III according to
EN 676)
1.1
2820
1.20
6 A
IP 44
IONISATION PROBE
73
40
- 10
80
80.5
13.1
500
TBG 80 LX PN V
2
1
No. 4 M 12
No. 4 M 12
No. 4 Ø 12