Design and function

4
Design and function
Design
VAC mainly consist of a ground plate with suction cup(s) (1), a 2/2-way
Function
ball valve (3) and a vacuum nozzle (4). By actuating the 2/2-way valve (3)
a vacuum is generated with the vacuum nozzle (4). As a result, the VAC
attaches itself with the suction cup(s) (1) to the mounting surface.
Hose set HG N
with DRV
When the compressed air supply line is open, the VAC is permanently
supplied with compressed air through the hose set.
The vibrator is switched on and off by actuating the 3/2-way manual slide
valve (3).
The hose set HG ... N with DRV is equipped with a throttle check valve (2).
By using the throttle check valve, it is possible to set the pressure applied
to the vibrator and thereby the frequency of the vibrator.
1
Ground plate with suction cup
2
Hose set connection
3
2/2-way ball valve
4
Vacuum nozzle
5
Silencer
6
Vibrator
1
Vibrator connection
2
Throttle check valve
(DRV)
3
3/2-way manual slide valve
4
Compressed air connection
5
VAC connection
13