Omron A22TK Quick Start Manual page 7

Key-type selector switch with direct opening mechanism
Table of Contents

Advertisement

A22TK
Specifications
Approved Standard Ratings
• UL, cUL (File No. E41515): 6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive): 3 A at 220 VAC
• CCC (GB14048.5): 3 A at 240 VAC, 1.5 A at 24 VDC
Certified Standards
Certification body
UL *1
TÜV SÜD
CQC(CCC)
KOSHA
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained. (Certification has been obtained for the Switch Unit only)
Ratings
Contacts (Standard load)
Rated carry current
Rated voltage
(A)
24 VAC
110
220
380
440
10
24 VDC
110
220
380
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the
following conditions.
(1) Ambient temperature: 20±2C°
(2) Ambient humidity: 65±5% RH
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Characteristics
Item
Allowable operating
frequency
Insulation resistance
Dielectric strength
Vibration resistance *1
Shock resistance
Durability
Ambient operating temperature *2
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (tracking characteristic)
Degree of contamination
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will
become rough once they have been used and contact reliability for smaller loads may be reduced.
7
Standards
UL508, C22.2 No.14
EN60947-5-1
(certified direct opening mechanism)
GB14048.5
EN60947-5-1
AC15
(V)
(inductive load)
(resistive load)
10
5
3
2
1
-
Model
Mechanical
30 operations/minute max.
Electrical
30 operations/minute max.
100 MΩ min. (at 500 VDC)
Between terminals
2,500 VAC, 50/60 Hz for 1 min.
of same polarity
Between each
2,500 VAC, 50/60 Hz for 1 min.
terminal and ground
10 to 55 Hz, 1.5-mm double amplitude (within 1 ms)
Destruction
1000 m/s
Malfunction *1
250 m/s
Mechanical
100,000 operations min.
Electrical
100,000 operations min.
-20 to +70°C
35% to 85%RH
-40 to +70°C
IP65 *3
Class II
175
3 (EN60947-5-1)
File No.
E41515
Consult your OMRON
representative for details.
2003010303070635
2009-156
Rated current (A)
AC12
DC13
(inductive load)
10
10
6
-
3
2
1.5
0.5
-
0.2
0.1
A22TK
2
2
max.
DC12
(resistive load)
-
10
2
0.6
0.2