Tightness inspection

Hoses check
Check that the hose "A" (fig. 15) is in good condition
and correctly fixed.
If the hose is damaged, broken or badly connected to
the unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in the inlet and on the baffle
plate inside the filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in figure 15.
Cover tightness check
If the gasket "A" (fig. 11) under the cover "D" has
become slack, unscrew the screws "B" that lock the
closing hooks "C" in place and allow them to slide
downwards until the deck "D" closes perfectly.
Now tighten the locking screws "B".
Replace the gasket "A" (fig. 11) if the degree of
tightness is still not optimum.
Filtering chamber tightness check
If the gasket "A" (fig. 12) between the container and
the filtering chamber "C" fails to guarantee tightness:
-
loosen the four screws "B" that lock the filtering
chamber "C" against the vacuum cleaner
structure;
-
allow the filtering chamber "C" to lower down and
tighten the screws "B" once it has reached the
tightness position.
The gasket must be replaced if it is torn, cut, etc...
Replace the gasket "A" if the degree of tightness is still
not optimum.
01/2015

Vacuum cleaner disposal

Dispose of the vacuum cleaner in compliance with the
laws in force.
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The above symbol "H" (fig. 1), which is present on the
product or o in its documentation, indicates that the
product can not be disposed of with other domestic
waste at the end of its cycle of life.
To prevent damages to the environment or the health
caused by improper waste disposal, please separate
this product from other waste and recycle it responsibly
in order to support the sustainable reuse of material
resources.
Users should contact the supplier and check the
purchase contract terms and conditions.

Wiring diagrams

See fig. 18.
Wiring diagram list
Part
Name
1
Plug
2
Circuit breaker
3
Circuit breaker
4
Motor
11
15ATEX
GB
C301