Celerity Fc-44Es Adapter - ATTO Technology Celerity FC-41EL Installation And Operation Manual

Celerity fibre channel host adapters
Hide thumbs Also See for Celerity FC-41EL:
Table of Contents

Advertisement

Celerity FC-44ES Adapter

The Celerity FC-44ES uses PCI Express Interconnect
and 4-Gigabit Fibre Channel to provide 4-Gb FC
speeds of up to 800 MB/sec. per channel. The FC-
44ES supports high-definition video, rich content
databases and other high bandwidth environments.
The FC-44ES uses PCI Express, a serial, high-speed
connection that supports aggregate throughput up to 4
GB/sec. (x8 PCIe) full-duplex. Software compatible
with existing PCI and PCI-X products, the FC-44ES
uses the same device drivers as other Celerity FC
family products, simplifying installation and support.
Hardware specifications
• 4 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
5 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Advanced FC capabilities
• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb,
2-Gb and 1-Gb Fibre Channel
• Supports target and initiator modes
• Supports Windows FDMI and WMI
• Supports exclusive ATTO Advanced Data
Streaming (ADS) Technology
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
Interconnect
• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0
Environmental & physical specifications
• Conforms to PCI standard height, half length
form-factor specifications
• Length: 6.525 inches
• Height: 3.81 inches
• Operating temperature: 0-45ºC (32-113ºF)
• Storage temperature: -40 to 70ºC (-40 to 158ºF)
• Relative humidity: 10 to 90% non-condensing
• 12V@ 2.1A (max.)
• 3.3V @ 3.0A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for
each channel
• 4 pluggable optical LC SFP transceivers
included
Software specifications
• Windows Server 2008, 2003, 2000; Vista, XP
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux (2.4 and 2.6 kernel)
• SUSE Linux (2.6 kernel)

Advertisement