Celerity Fc-82En Adapter - ATTO Technology Celerity FC-41EL Installation And Operation Manual

Celerity fibre channel host adapters
Hide thumbs Also See for Celerity FC-41EL:
Table of Contents

Advertisement

Celerity FC-82EN Adapter

The ATTO Celerity FC-82EN leverages two next-
generation storage technologies: PCIe 2.0
interconnect and 8-Gigabit Fibre Channel.
With 8-Gb FC speeds of up to 1600 MB/sec. per
channel, the Celerity FC-82EN supports the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
Technical specifications
• Two independent Fibre Channel ports
• 1600 MB/sec. maximum throughput per channel
in full-duplex mode
• 8 GB/sec. FC data-transfer rate
• Conforms to PCI Express Low Profile form-
factor specifications
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 41
• Advanced Data Streaming (ADS) Technology
Advanced FC capabilities
• Supports SNIA HBA API
• Backward compatible with 4-Gb and 2-Gb Fibre
Channel
• Supports target and initiator modes
• Supports Windows® FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
interconnect
• Conforms to PCI Express Base Spec 2.0
Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
3 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Environmental & physical specifications
• Length: 6.6 inches
• Height: 2.731 inches
• Operating temperature: 0-40 ºC (32-113 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 5.9W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
• External LEDs for on-line and speed status for
each channel
• Two pluggable 8-Gb optical LC SFP+ modules
included
Software specifications
• Windows Server 2008, 2003; Vista, XP
• Mac OS X (10.4.x, 10.5.x)
• Red Hat Linux (2.6 kernel)
• SUSE Linux (2.6 kernel)
• Fedora Linux (7 & 8)

Advertisement

Table of Contents
loading