Galvanized tilt fan with cone

Advertisement

Quick Links

Instruction Manual
WF54GCX
WF54 Galvanized Tilt Fan with Cone
Models:
WF54xxTxCP
WF54xxTxCXP
© Munters Corporation, August 2019
WF54xxTxCJ
WF54xxTxCXJ
WF54
Galvanized
54" Tilt Fan
with Cone
WF54GC
1
QM1073r8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WF54 T CP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Munters WF54 T CP Series

  • Page 1 WF54 Galvanized 54” Tilt Fan Instruction Manual with Cone WF54GCX WF54GC WF54 Galvanized Tilt Fan with Cone Models: WF54xxTxCP WF54xxTxCJ • • WF54xxTxCXP WF54xxTxCXJ • © Munters Corporation, August 2019 QM1073r8...
  • Page 2: Warranty

    Instructions for use and maintenance Thank You: Thank you for purchasing a Munters WF54 Tilt Wall Series fan. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service.
  • Page 3 Unpacking the Equipment Parts List Fan Dimensions 2. Installation Instructions 3. Electrical Wiring Wiring Recommended Wire Routing 4. Operation 5. Maintenance 6. Winterizing Winterizing Winter Weather Protection 7. Troubleshooting 8. Exploded View and Parts List 16-17 © Munters Corporation, August 2019 QM1073r8...
  • Page 4: Unpacking The Equipment

    .32”IDx.75”ODx1”L. Spacer, Black, NY NOTE: Discharge cone is designed to mount on fan outlet for increased airflow and to support the exhaust guard. A shutter or guard must be mounted on the fan inlet. © Munters Corporation, August 2019 QM1073r8...
  • Page 5 58” ⁄ ” ⁄ ” ⁄ ” ⁄ ”W. x 62 ⁄ ”H. WF54 54GCX ⁄ ” ⁄ ” 12 ⁄ ” 56” 58” ⁄ ” 66” 59” ⁄ ”W. x 62 ⁄ ”H. © Munters Corporation, August 2019 QM1073r8...
  • Page 6: Installation Instructions

    Framing cut at Catalog 12° to match 2 x 4 Framing Concrete Framing fan housing ”W. x ”H. ”W. x ”H. WF54 ⁄ ⁄ ⁄ Chart A Figure 1D Greater than 4" Wall Thicknesses © Munters Corporation, August 2019 QM1073r8...
  • Page 7 60½" 56" 56" Figure 4A Figure 4B Figure 4C Step 6 Make electrical connections to fan motor per instructions provided with fan or as shown on motor. See Electrical Wiring Section on page 5. © Munters Corporation, August 2019 QM1073r8...
  • Page 8: Electrical Wiring

    For electrical connection requirements, refer to diagram on motor nameplate and to information enclosed with the Munters environmental control to be used. After wiring check for proper motor rotation.
  • Page 9: Shutter Installation

    See Figure 8A. Fasten shutter in place by rotating the side and top shutter clips over the shutter flanges. See Figure 8B. Shutter Clip Side Shutter Clip Bottom Shutter Clip Figure 8A Figure 8B © Munters Corporation, August 2019 QM1073r8...
  • Page 10: Operation

    Minimum operating frequency of 30 Hz. Will require three pole contractors with overload protection (by others). Moving Parts: Disconnect Power Before Servicing. WARNING Do Not Power Wash Electrical Devices. © Munters Corporation, August 2019 QM1073r8...
  • Page 11: Maintenance

    Wiring should be secure and in good condition. Remove any dust build-up from control case and sensor using a soft brush or cloth. NEVER CLEAN Do Not Power Wash Electrical Devices. ELECTRICAL EQUIPMENT WITH A PRESSURE WASHER! © Munters Corporation, August 2019 QM1073r8...
  • Page 12 Mark 2¹⁄₂ on the tensioner arm. Hold tensioner at this setting and tighten 10mm bolt to 40 ft.-lbs [54 N-m] torque. 10mm Bolt ¹⁄₂ Mark 2 Alignment Tensioner Arm Mark on Base © Munters Corporation, August 2019 QM1073r8...
  • Page 13: Winter Weather Protection

    Munters Product and System manufacturers recommendations. The supplier listing above is given Warranties do not cover cone or fan as a reference only. Munters does not endorse any specific snow guard product and no performance warranty is implied. damage from external sources.
  • Page 14: Troubleshooting

    2. Frequency drive improperly adjusted 2. See operation, Step 2 for adjustments guidelines Excessive 1. Tighten fasteners 1. Motor loose on mount Vibration 2. Replace propeller 2. Propeller damaged 3. Repair or replace motor or propeller shaft © Munters Corporation, August 2019 QM1073r8...
  • Page 15 This page left blank intentionally © Munters Corporation, August 2019 QM1073r8...
  • Page 16: Exploded View

    Exploded View © Munters Corporation, August 2019 QM1073r8...
  • Page 17 "W. x 60 "H., all plastic or aluminum blade/galvanized frame * Parts listed are for standard configuration with 1.5 HP motor and other drive components operating on 60Hz power. Contact office for other configurations. © Munters Corporation, August 2019 QM1073r8...
  • Page 18 WF54 Tilt Fan with Cone is developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66.

This manual is also suitable for:

Wf54 t cj seriesWf54 t cxp seriesWf54 t cxj seriesWf54Wf54gcxWf54gc