Assembly and installation
Start-up carried out by an authorised TAC which issues the guarantee and the maintenance logbook
Ventilation of the room
The flue/chimney must only receive the discharge from the stove
The flue must have: no more than 2 bends
a chimney pot above the reflux area
discharge pipes in suitable material (stainless steel is recommended)
if the pipes pass through or near any flammable materials (e.g. wood), all
fire-prevention precautions must be taken.
Use
The pellets must be of good quality and not damp
The crucible and the ash pan must be clean and correctly positioned
The door must be securely closed
The crucible must be well inserted into its seat
REMEMBER to ALWAYS VACUUM THE CRUCIBLE BEFORE IGNITION
If the stove does not light, do NOT repeat ignition before having emptied the crucible.
CHECK LIST
no more than 2 metres of horizontal sections