La San Marco TOP 85 Use And Maintenance page 62

Table of Contents

Advertisement

Available languages

Available languages

10.9 Preinfusion activation screen
Screen 24 a
PREBREWING
ENABLE
Screen 24 b
PREBREWING
DISABLE
Screen 25
PREBREWING
SELECT GROUP
10.10 Single dose preinfusion screen
Screen 26
PUMP
Preinfusion activation technical level programming screen.
This technical level programming screen is used to activate or deac-
tivate preinfusion.
Use the + / - buttons to activate or deactivate preinfusion.
Press Ok to confirm the change.
Default setting: NOT ACTIVE
Press NEXT to go to the next screen if preinfusion is active, if preinfu-
sion is set as not active screen 27 will not be displayed.
If no button is selected within 30 seconds, the machine ready screen
will appear automatically (screen 2).
Pressing ESC returns to the machine ready screen.
Set preinfusion technical level programming screen.
When this screen is displayed, preinfusion can be programmed for all
buttons for every single unit.
All buttons are on, selecting one of the buttons (for example, single long
dose button for unit 1) will display screen 26.
Press NEXT to go to screen 27.
If no button is selected within 30 seconds, the machine ready screen will
appear automatically (screen 2).
Pressing ESC returns to the machine ready screen (screen 2).
Single dose preinfusion programming screen.
After selecting the unit on the previous screen or on this screen, the
unit will start to flash and a screen will appear indicating the unit and
set values for tON and tOff.
This screen can be used to adjust the tON and tOff value, within
the permitted limits, by simply increasing or increasing it using the +
and – buttons and in steps of 0.1 seconds, after selecting them with
the  /  buttons.
Press Ok to save the value and return to screen 25, or press another
button for another unit to display the preinfusion setting for that unit.
Setting tON to a value of 0 seconds disables preinfusion for all but-
tons for the selected unit.
Press NEXT to go to the next screen.
If no button is selected within 30 seconds, the preinfusion selection
screen will appear automatically (screen 25) without saving the change.
Pressing ESC returns to the dose selection screen (screen 24) with-
out saving the change.
programmed dose
total time dispensing
61