1. DESCRIPTION
The display cabinet, is available in two depthst, four different lenghts and in two different heights. The low-tempera-
ture version of this showcase is meant for the preservation of ice-creams and frozen food (class L). Its main features
and dimensions are clearly illustrated in drawings 1, 2, 3, on page 3. As for its weights, crating included and exclu-
ded, see table I on page 4. A wide variety of optional accessories enabling enhanced functions is also available. To
this respect, contact the authorised after-sales service only.
2. TRANSPORTATION
The display cabinet is contained in a specially crated package that enables transportation by the use of fork-lift trucks.
Handle the machine on its own pallet or on a similar platform; use a fork lift, either manual or electric, provided it is
adequate for handling such appliances and it has the requisite lifting capacity (see page 4 - fig. 4 and table I).
Handling is reserved to the authorised after-sales service.
3. DELIVERY AND STORAGE
Prior to accepting the case from the carrier, check the conditions of the package. If it is showing visible damage, the
machine too may have been impaired. In this case, unpack the machine in the presence of the carrier and sign, thou-
gh with reservation, the delivery bill. The manufacturer assumes no liability for damage caused by transportation or
wrong handling during storage. Unpacking is reserved for the authorised after-sales service. Storing temperature must
be between -25°C and +55°C, air humidity between 30% and 95%. Keep the cabinet safe from direct sunlight and
from the elements.
4. INSTALLATION AND AMBIENT CONDITIONS
The display case must not be installed in premises containing explosive gas substances. It can neither be
used in the open nor exposed to the rain.
Before connecting the case make sure that its rating plate data correspond to the features of the existing electrical
installation (see page 5 - fig. 8 and tab. III). For correct operation, the machine must be placed on a level floor (see
page 4 - fig 5), far from sources of heat and/or direct sunlight, doors, windows, fans or ventilation outlets (see page
4 - fig.6). It must also be granted a reasonable free front area for customer service.
The display case must be housed in a room conforming to the ambient requirements mentioned in page 4 -
fig. 7 and tab. II.
IMPORTANT: placing fixed panels on the top of the cabinet is advised against, as this part must be accessi-
ble for servicing purposes.
5. ELECTRICAL CONNECTION
IMPORTANT: ahead of the case there must be an MULTIPOLAR CUT-OFF SWITCH WITH CONTACTS SPACING AT
LEAST 3 MM AND WITH THE ADEQUATE CIRCUIT-BREAKING POWER. (see fig. 19). The position of the cut-out swit-
ch must enable its actuation in any emergency situation (maximum distance 3 m). Show the position of the cut-out
switch to any prospective operator.
The refrigerator must be installed by professionally qualified personnel, in accordance with the instructions provided
by the manufacturer and local regulations. Incorrect installation may cause harm to persons, animals and property.
The manufacturer assumes no responsibility for such damage.