6.2 Wiring Method - Yoshitake DP-10 Series Instruction Manual

Table of Contents

Advertisement

6.2 Wiring Method
(1) Wiring differs according to the voltage, AC100V or 200V (AC110V or 220V/AC120
or 240V). Wire the coil according to the instruction on the label attached to the coil. In
order to prevent faulty or erroneous wiring, especially wiring in a dark or narrow space, it
is recommended that each of the lead wires be clearly identified with different colors
that can be easily recognized.
(2) Do not unnecessarily pull the lead wires, and avoid subjecting them to excessive
loads when wiring and use.
(3) Use electric wires which have a core of 0.75mm
(4) Use a fuse (2 to 3) to protect the electric circuit. Use a circuit protector as follows
if the valve is used in a fuel supply system.
Rating voltage 100V: 0.5A circuit protector
Rating voltage 200V: 0.3A circuit protector
● DC coil has two non-selective lead wires (red and black).
2
or more.
Switch
Power
-11-
Circuit
Fuse
Protector
■EPDT-028d■
Coil