6.1 Setting the communications parameters with the DIP switches
Disconnect the printer from the power supply,
Remove the cover from the base plate.
Setting the communications parameters with the DIP switches
DSW1 :
SW Function
1
Data receive error
2
Receive buffer capacity
3
Handshaking
4
Word length
5
Parity check
6
Parity selection
7
Transmission speed
8
BUSY condition
16
DSW1
DSW2
On
Ignored
40 bytes
XON/XOFF
7 bits
yes
Even
4800 bps
Receive buffer full Receive buffer
Off
Prints „?"
4 KB
DTR/DSR
8 bits
no
Odd
9600 bps
full or Offline