AIR CONDITIONERS Serie: X-REVO - XX19 E Serie: X-REVO - XX19 XE Serie: X-REVO - XX19 EX Unità Esterna / Outdoor Unit IT IT MANUALE INSTALLAZIONE ED ISTRUZIONI PER L’USO MANUALE INSTALLAZIONE ED ISTRUZIONI PER L’USO USE AND INSTALLATION MANUAL USE AND INSTALLATION MANUAL...
Page 2
IT IT pagina 4 page 49 Vi ringraziamo per la fiducia concessaci nell’acquisto di questo prodotto. Thanks you for the trust you have shown by purchasing this produtc. Carefully Vi invitiamo a leggere attentamente questo manuale dove sono riportate le read this manual which contains the specifications and all the information caratteristiche tecniche e tutte le informazioni utili per ottenere un corretto useful for the correct functioning.
Page 3
IT IT INDICE 1. PRESENTAZIONE DEL PRODOTTO ..4 9. ANOMALIE DI FUNZIONAMENTO ..23 1.1 Composizione del climatizzatore 9.1 Segnalazioni visibili sulla scheda di controllo delle unità esterne 1.2 Unità esterna X-REVO-XX19E: X-REVO-0919E, X-REVO-1219E, X-REVO-1819E, 1.3 Tabella identificazione prodotti e X-REVO-2419E 1.4 Accessori forniti in dotazione all’unità...
Page 4
IT IT 1. PRESENTAZIONE DEL PRODOTTO 1.3 Tabella identificazione prodotti 1.1 Composizione del climatizzatore La seguente tabella serve ad identificare il climatizzatore completo o la singola unità acquistata: I climatizzatori sono della tipologia “Split System” con scambio termico aria-aria: Tipo Potenzialità...
Page 5
IT IT 2. AVVERTENZE 2.1 Attenzioni e pericoli Significato dei simboli Prima di continuare le operazioni leggere il manuale Prima di utilizzare il climatizzatore leggere attentamente il presente per l'operatore manuale di istruzioni. Il produttore declina ogni responsabilità per even- Prima di eseguire interventi di manutenzione e riparazione, tuali danni derivanti dalla non osservanza delle seguenti avvertenze.
Page 6
IT IT 2. AVVERTENZE Qualora si verifichi un malfunzionamento è consigliabile spegnere prima Utilizzare il climatizzatore solo per climatizzare il locale. il condizionatore col telecomando, prima di scollegare l'alimentazione Non usare il condizionatore per altri scopi, es. conservazione e protezione elettrica.
Page 7
IT IT 2. AVVERTENZE Usare solo fusibili dell’amperaggio appropriato. Non versare o spruzzare acqua sul climatizzatore. (Mai usare pezzi di cavo/filo per effettuare sostituzioni provvisorie. Questo potrebbe non solo danneggiare l’unità ma anche causare un incendio). 3. INFORMAZIONI IMPORTANTI 3.1 Conformità ai regolamenti 3.2 Grado di protezione degli involucri (Codice IP) I climatizzatori sono conformi alle direttive europee:...
Page 8
IT IT 3. INFORMAZIONI IMPORTANTI 3.4 Limiti di funzionamento - Valori unità esterne Temperatura esterna Unità esterna Raffrescamento °C Riscaldamento °C X-REVO-0919E -15÷43 -15÷24 X-REVO-1219E -15÷43 -15÷24 X-REVO-1819E -15÷43 -15÷24 X-REVO-2419E -15÷43 -15÷24 X-REVO-0919EX -15÷48 -15÷24 X-REVO-1219EX -15÷48 -15÷24 X-REVO-1819EX -15÷48 -15÷24 X-REVO-1419DE...
Page 9
IT IT 3. INFORMAZIONI IMPORTANTI 1. DESCRIZIONE DEI COMPONENTI CONTROLLO DELL’ESPOSIZIONE/PROTEZIONE INDIVIDUALE Valori limite per l’esposizione professionale Parametri di controllo Per nessun componente è stato definito un limite di esposizione. Componente critico Tipo Valore Osservazioni Valori DNEL difluorometano Lavoratori - inalazione 7035 Tossicità...
Page 10
IT IT 4. MOVIMENTAZIONE E TRASPORTO Movimentazione di unità pesanti Disimballo Le operazioni di disimballo devono essere eseguite con cura, al fine di non danneggiare l’involucro delle unità, se si opera con coltelli o taglierini per aprire l’imballo in cartone. ATTENZIONE Dopo aver tolto l’imballo assicurarsi dell’integrità...
Page 11
IT IT 5. POSIZIONAMENTO DELL'UNITÀ 1. DESCRIZIONE DEI COMPONENTI (e) In veicoli o imbarcazioni. Il condizionatore deve essere collocato in un luogo ben ventilato e facilmente (f) In cucine con molti fumi di oli ed alta percentuale d’ umidità. accessibile. (g) Vicino a macchine che emettono onde elettromagnetiche.
Page 12
IT IT 5. POSIZIONAMENTO DELL'UNITÀ Distanze minime funzionali UNITÀ ESTERNA A (mm) B (mm) C (mm) D (mm) E (mm) > 300 > 600 > 300 > 2000 > 600 Distanza tra le unità Dislivello Dislivello Distanza Lunghezza Lunghezza Carica addizionale di massimo massima massima...
Page 13
IT IT 5. POSIZIONAMENTO DELL'UNITÀ 1. DESCRIZIONE DEI COMPONENTI 5.4 Dati dimensionali Unità Esterna Modello X-REVO-0919E X-REVO-1219E X-REVO-1819E X-REVO-2419E X-REVO-0919EX X-REVO-1219EX X-REVO-1819EX X-REVO-1419DE X-REVO-1819DE X-REVO-2419TE 1080 1090 X-REVO-3619QE 1080 1090...
Page 14
- Operazioni non adeguate possono provocare gravi danni all'utente. - La lista dei centri assistenza è disponibile nel sito web www.emmeti.com. La corretta installazione del climatizzatore ne garantisce l’efficiente funzionamento. Vi invitiamo pertanto a seguire attentamente le indicazioni sul posizio- namento, l’installazione, i collegamenti e il collaudo presenti in questi...
Page 15
IT IT 6. INSTALLAZIONE DELL'UNITÀ ESTERNA 1. DESCRIZIONE DEI COMPONENTI 6.3 Tubazioni circuito frigorifero Le connessioni per le tubazioni frigorifere sono con tenuta a cartella e bocchettone.L’unità esterna contiene tutta la carica del sistema refrigerante ed è dotata di valvole con connessione a bocchettone e presa di servizio. Modello Linea liquido Linea gas...
Page 16
IT IT 6. INSTALLAZIONE DELL'UNITÀ ESTERNA Connessione dei tubi ai raccordi Isolamento delle tubazioni Connettere le tubazioni ai raccordi delle unità. Prima di eseguire le operazioni di cartellatura del tubo è indispensabile Per il serraggio stringere i bocchettoni con una coppia pari a: isolarlo e poi inserire i bocchettoni sul tubo.
Page 17
IT IT 6. INSTALLAZIONE DELL'UNITÀ ESTERNA 1. DESCRIZIONE DEI COMPONENTI 6.4 Allacciamento elettrico - Utilizzare un cavo multipolare del tipo H07RN-F I collegamenti elettrici devono essere eseguiti da personale qualificato e - Per lunghezze superiori ai 15 m adottare le sezioni standard immedia- nel rispetto delle normative vigenti nel luogo d’installazione dell’unità...
Page 18
IT IT 6. INSTALLAZIONE DELL'UNITÀ ESTERNA Posizionamento dei tubi dei cavi I cavi di collegamento e il tubo di condensa devono essere fissati insiemeai tubi del refrigerante, usando nastro protettivo a Nastratura alluminata b Tubazioni frigorifere Scarico condensa unità interna ...
Page 19
IT IT 6. INSTALLAZIONE DELL'UNITÀ ESTERNA 1. DESCRIZIONE DEI COMPONENTI Collegamenti Unità DUAL Collegamenti Unità TRIAL Collegamenti Unità QUADRIAL...
Page 20
IT IT 7. CARICA E COLLAUDO DELL'IMPIANTO 7.1 Test di funzionamento Nota: dopo che l’unità viene spenta, o dopo che viene variata la modalità di (la prima accensione va fatta funzionamento, il compressore non si rimette in moto prima di 3 min. assolutamente in modalità...
Page 21
IT IT 7. CARICA E COLLAUDO DELL'IMPIANTO 7.2 Vuoto e carica Attacco Raccordo a del circuito frigorifero con R32 linea flessibile Valvola 3 vie - Le operazioni sotto indicate devono essere eseguite dopo aver tolto l’alimentazione elettrica al climatizzatore. Tappo valvola b - L’unità...
Page 22
IT IT 1. DESCRIZIONE DEI COMPONENTI 8. SMALTIMENTO 8.1 Nota informativa RAEE 8.3 Norme di smaltimento dell'imballaggio del Ai sensi dell’art. 26 del Decreto Legislativo 14 marzo 2014, n. 49 nuovo climatizzatore “Attuazione della Direttiva 2012/19/UE sui rifiuti di apparecchia- ture elettriche ed elettroniche (RAEE)”.
Page 23
IT IT 9. ANOMALIE DI FUNZIONAMENTO 9.1 Segnalazioni visibili sulla scheda di controllo delle unità esterne X-REVO-XX19E : X-REVO-0919E, X-REVO-1219E, X-REVO-1819E, X-REVO-2419E I codici di errore vengono segnalati dal tipo di lampeggi delle spie LED 1, LED 2, LED 3 presenti sulla scheda di controllo dell'unità...
Page 24
IT IT 9. ANOMALIE DI FUNZIONAMENTO CODICE / DESCRIZIONE / DESCRIPTION LED1 LED2 LED3 POSSIBILE CAUSA / POSSIBLE CAUSE CODE (GB) (IT) a. the communication a. il cablaggio del cavo di comunicazione è cable connect loose; allentato; b. the communication b.
Page 25
IT IT 9. ANOMALIE DI FUNZIONAMENTO CODICE POSSIBILE CAUSA / POSSIBLE CAUSE DESCRIZIONE / DESCRIPTION LED1 LED2 LED3 (GB) (IT) / CODE a. the indoor coil temper- a. il cavo di collegamento del sensore di Protezione antigelo in ature sensor connect temperatura dello scambiatore interno è...
Page 26
IT IT 9. ANOMALIE DI FUNZIONAMENTO I LED lampeggiano ogni 2 secondi (2 sec.) per segnalare le seguenti anomalie: CODICE POSSIBILE CAUSA / POSSIBLE CAUSE DESCRIZIONE / DESCRIPTION LED1 LED2 LED3 (GB) (IT) / CODE Protezione surriscaldamento a. Radiator sensors fail a.
Page 27
IT IT 9. ANOMALIE DI FUNZIONAMENTO 9.2 Segnalazioni visibili sulla scheda di controllo delle unità esterne X-REVO - XX19 XE , X-REVO - XX19 EX I codici di errore vengono segnalati dal tipo e numero di lampeggi delle spie LED presenti sulla scheda di controllo dell'unità esterna, come meglio specificato di seguito: Modelli X-REVO-0919EX, X-REVO-1219EX, X-REVO-1819EX: Il LED1 indica la prima cifra del numero del codice di errore , il LED2 indica la seconda cifra del codice di errore e il LED3 indica un errore della...
Page 28
IT IT 9. ANOMALIE DI FUNZIONAMENTO Ad esempio, errore scheda di controllo principale dell'unità esterna codice 32: 600 ms 600 ms 600 ms 600 ms 600 ms 600 ms LED2 ON OFF ON OFF ON ON OFF ON OFF ON 600 ms 600 ms 5000 ms...
Page 29
IT IT 9. ANOMALIE DI FUNZIONAMENTO Attenzione! Spegnere il climatizzatore con il telecomando. Prima di effettuare qualsiasi intervento sulle unità accertarsi che sia stata tolta l’alimentazione elettrica generale. Codici di errore riferiti all'unità esterna: Cod. Descrizione Errore Possibili cause Cosa fare Note 1.
Page 30
IT IT 9. ANOMALIE DI FUNZIONAMENTO Cod. Descrizione Errore Possibili cause Cosa fare Note Solo per 1. Alimentazione trifase non corretta; 1. Verifica il collegamento facendo modelli con Voltaggio assente su 2. I collegamenti esterni sono errati; riferimento allo schema generico alimenta- una fase 3.
Page 31
IT IT 9. ANOMALIE DI FUNZIONAMENTO Cod. Descrizione Errore Possibili cause Cosa fare 1. Cablaggio allenatao tra scheda di controllo e 1. Ricollegare il cavo tra la scheda di controllo scheda inverter e la scheda inverter; Errore comunicazione IPM e 2.
Page 32
IT IT 9. ANOMALIE DI FUNZIONAMENTO Codici di errore riferito all'unità interna Codice Descrizione Errore Possibili Cause Cosa Fare di Errore Protezione tubo di 1. Il livello dell’acqua della bacinella di drenaggio 1.1 Verificare se c’è qualcosa che ostruisce lo scarico o scarico supera il livello di sicurezza;...
Page 33
IT IT 9. ANOMALIE DI FUNZIONAMENTO Codice Descrizione Errore Possibili Cause Cosa Fare di Errore FE (254) Errore di comunica- 1. Il cablaggio tra il controllo a filo e la scheda di control- 1. Ricollegare il controllo a filo alla scheda di controllo zione tra la scheda di lo dell’unità...
Page 34
IT IT 9. ANOMALIE DI FUNZIONAMENTO Nota 1: Quando l’unità interna non si accende , o l’unità interna si spegne da sola dopo 30 secondi, non può visualizzare il codice di errore. Controllare il collega- mento della scheda di controllo. Nota 2: Se l’unità...
Page 35
IT IT 9. ANOMALIE DI FUNZIONAMENTO Codici di errore scheda inverter Modelli X-REVO-0919EX, X-REVO-1219EX, X-REVO-1819EX, X-REVO-1419DE, X-REVO-1819DE Sulla scheda inverter è presente una spia che lampeggia in caso di anomalie. Il numero di lampeggi indica il codice di errore Codice Descrizione Errore Possibile Causa Cosa fare Sovratensione CC dell'inverter...
Page 36
IT IT 9. ANOMALIE DI FUNZIONAMENTO Codici di errore scheda inverter Modelli X-REVO-2419TE, X-REVO-3619QE Sulla scheda inverter è presente una spia che lampeggia in caso di anomalie. Il numero di lampeggi indica il codice di errore Codice Descrizione Errore Possibile Causa Cosa fare 1.
Page 37
IT IT 9. ANOMALIE DI FUNZIONAMENTO Istantanea interruzione di 1. L’alimentazione non è stabile 1.Controllare l’alimentazione corrente 2. Interruzione di corrente istantanea 2. Sostituire la scheda inverter 3. Guasto scheda inverter Codice Descrizione Errore Possibile Causa Cosa fare 1.Tensione di ingresso troppo bassa 1.Controllare l'alimentazione Bassa tensione CC 200V 2.Guasto scheda inverter...
Page 41
IT IT 10. SCHEMI ELETTRICI Schema elettrico TRIAL 24 kBtu - X-REVO-2419TE...
Page 42
IT IT 1. DESCRIZIONE DEI COMPONENTI 10. SCHEMI ELETTRICI Schema elettrico QUADRIAL 36 kBtu - X-REVO-3619QE...
Page 43
IT IT 10. SCHEMI ELETTRICI Legenda GB Legenda IT Legenda GB Legenda IT TERMINAL PANEL Morsettiera unità interna Temperatura ambiente /della stan- ROOM TEMPERATURE BLU or BU Colore blu BLK or BK Colore nero PIPE TEMPERATURE Temperatura delle tubazioni BRN or BN Colore marrone BRN(BLK) Colore marrone (nero)
Page 44
IT IT 11. CIRCUITO FRIGORIFERO SINGLE 9, 12, 18, 24, kBtu Unità esterna Unità Interna LATO GAS Valvola Valvola 3-vie 4-vie Silenziatore Scarico Scambiatore di calore Accumulatore (Evaporatore) Aspirazione Compressore Scambiatore LATO di calore LIQUIDO (condensatore) Filtro Valvola di espansione Filtro Valvola elettronica/capillare...
Page 45
IT IT IT IT 11. CIRCUITO FRIGORIFERO 1. DESCRIZIONE DEI COMPONENTI DUAL 14, 18, kBtu Unità Interna Unità esterna Unità A Valvola 4-vie Unità B Unità B Filtro Unità A Ciclo Raffrescamento Ciclo Riscaldamento TRIAL 24 kBtu / QUADRIAL 36 kBtu Unità...
Page 46
IT IT IT IT 1. DESCRIZIONE DEI COMPONENTI...
Page 47
Dichiara inoltre di aver preso visione della Informativa sui dati personali disponibile anche sul sito internet di Emmeti S.p.A. EMMETI spa - Via brigata Osoppo, 166 - 33074 Vigonovo frazione di Fontanafredda (PN) - Italia - Tel.0434567911 - Fax 0434567901 - www.emmeti.com...
Page 49
INDEX 1. INTRODUCTION TO THE PRODUCT ..50 8. DISPOSAL ......... 68 1.1 Air conditioner composition 8.1 Information note WEEE directive 2012/19/EU 1.2 Outdoor unit 8.2 Disposal rules for the old air conditioner 1.3 Product identification table 8.3 Disposal rules of the new air conditioner packaging 1.4 Accessories supplied with the outdoor unit 8.4 Battery disposal 9.
Page 50
1. INTRODUCTION TO THE PRODUCT 1.3 Product identification table 1.1 Air conditioner composition Through the following table you may identify the set model or the model of the single unit of the air conditioner. - The air conditioners are of the "Split System" type with air-to-air heat exchange: Type Potntiality...
Page 51
2. WARNINGS Attention and dangers Meaning of the symbols Before continuing the operations, read the operator manual Before using the air conditioner please read carefully the instructions ma- nual. Producer decline every responsibility for any damage caused by the Before doing any maintenance and repair works, read non-observing of the following warnings.
Page 52
2. WARNINGS If a device malfunction occurs, it is advisable to switch off the air condi- Use the air conditioner only to condition the room. tioner through its remote control, before disconnecting the power supply. Do not use the air conditioner for other purposes, for example: drying laundry, preserving food, breeding animals or cultivating vegetables.
Page 53
IT IT 2. WARNINGS Do not pour or spray water on the air conditioner. Please use fuses with the right amperage only. (Never use pieces of cable to make temporary replacements. This might cause fires too, not just a damage. 3.
Page 54
3. IMPORTANT INFORMATION 3.4 Operating limits - Outdoor Unit values Outdoor temperature Outdoor Temperature Cooling °C Heating °C X-REVO-0919E -15÷43 -15÷24 X-REVO-1219E -15÷43 -15÷24 X-REVO-1819E -15÷43 -15÷24 X-REVO-2419E -15÷43 -15÷24 X-REVO-0919EX -15÷48 -15÷24 X-REVO-1219EX -15÷48 -15÷24 X-REVO-1819EX -15÷48 -15÷24 X-REVO-1419DE -15÷48 -15÷24 X-REVO-1819DE...
Page 55
3. IMPORTANT INFORMATION 1. DESCRIZIONE DEI COMPONENTI EXPOSURE CONTROLS/PERSONAL PROTECTION Occupational exposure limit values Control Parameters No limit of exposure has been defined for any components Critical component Type Value Remarks DNEL values Difluoromethane Workers - inhalation 7035 Repeated dose toxicity Systemic, long term mg/m Critical component...
Page 56
4. HANDLING AND TRANSPORT Handling of heavy units Unpacking Unpacking operations have to be done carefully because the outdoor part of the units has not to be damaged when knifes or cutters are used to open the carton package. ATTENTION After unpacking make sure of the unit integrity.
Page 57
5. UNIT POSITIONING 1. DESCRIZIONE DEI COMPONENTI f) In kitchens with a lot of oil fumes and with high humidity percentage Air conditioner has to be placed in a well-ventilated and easy to reach place. g) Near machines issuing electromagnetic waves Air conditioner has not to be placed in the following places: h) Places with acid or alkaline fumes a) Places where there are machines oils or other oils fumes.
Page 58
5. UNIT POSITIONING Minimum functional distances Outdoor UNIT A (mm) B (mm) C (mm) D (mm) E (mm) > 300 > 600 > 300 > 2000 > 600 5.3 Distance between the units Difference in Difference in Reach Maximum Total length Amount of additional level maximum level maximum...
Page 59
5. UNIT POSITIONING 1. DESCRIZIONE DEI COMPONENTI 5.4 Dimensional data of the outdoor unit Model X-REVO-0919E X-REVO-1219E X-REVO-1819E X-REVO-2419E X-REVO-0919EX X-REVO-1219EX X-REVO-1819EX X-REVO-1419DE X-REVO-1819DE X-REVO-2419TE 1080 1090 X-REVO-3619QE 1080 1090...
Page 60
400 mm - Improper operations may cause serious harm to the user. - You can find a list of service centres at the website www.emmeti.com The right installation of the air conditioner assure its efficiency Therefore we invite you to follow the instructions carefully about positio- ning, installation, connexions and test listed in these manuals.
Page 61
6. INSTALLATION OF THE INDOOR UNIT 1. DESCRIZIONE DEI COMPONENTI 6.3 Refrigerating circuit piping The connections for the refrigerating piping are sealed with a flared end and flare-nut. The outdoor unit contains the whole charge of the refrigerating system and is equipped with valves with flare-nut connections and service fitting connection. Gas line Model Liquid line...
Page 62
6. INSTALLATION OF THE INDOOR UNIT Connecting the pipes to the fittings Insulating the pipelines - Connect the pipes to the fittings on the unit. - Before carrying out the flaring of the pipe, it is essential to insulate the -Secure by tightening the nuts to a torque of: pipe and then fit the nuts on the pipe.
Page 63
6. INSTALLATION OF THE INDOOR UNIT 1. DESCRIZIONE DEI COMPONENTI 6.4 Electrical supply - Use a multi-pole cable of type H07RN-F Electrical connections have to be done by qualified personnel, by observing - For lengths over 15m, use the next higher standard section, always the current rules in the place where the air conditioner unit has to be checking that in every case the voltage drop during operation is lower installed.
Page 64
6. INSTALLATION OF THE INDOOR UNIT Pipes and cables positioning The connection cables and the condensate plain pipe must be fixed toge- ther to the refrigerant pipes, using protective tape a Aluminized tape b Refrigeration piping Indoor unit condensation drain ...
Page 65
6. INSTALLATION OF THE INDOOR UNIT 1. DESCRIZIONE DEI COMPONENTI Connection whit DUAL unit Connection whit TRIAL unit Connection whit QUADRIAL unit...
Page 66
7. SYSTEM CHARGE AND TEST 7.1 Test running Note: When unit stops or operating mode has been changed, the com- (the first start-up absolutely must occur in pressor does not start working before 3 min. Cooling mode) When operating in Cooling mode, some frost may form on the Indoor unit or on piping.
Page 67
7. SYSTEM CHARGE AND TEST Note: 7.2 Draining and filling To determine the charge additional Considering the length of a single line. the refrigerating circuit with R32 Flexible hose - The operations indicated below must be carried out only after discon- Union 1 necting the air conditioner from the power supply.
Page 68
1. DESCRIZIONE DEI COMPONENTI 8. DISPOSAL 8.3 Disposal rules for the new air conditioner 8.1 INFORMATION NOTE WEEE packaging Directive 2012/19 / EU All of the air conditioner packing materials can be disposed of without harming the environment. The cardboard box must be cut into pieces and delivered to a paper collection container.
Page 69
9. ANOMALIES AND FUNCTIONING 9.1 Indications visible on the outdoor units control board X-REVO-XX19E : X-REVO-0919E, X-REVO-1219E, X-REVO-1819E, X-REVO-2419E Type of flashes of the LED 1, LED 2, LED 3 (lights on the outdoor unit control board) signals the error code. When the unit has an anomaly and the COMPRESSOR stops working, the LEDs on the outdoor unit control board will automatically show the sequence corresponding to the errors found.
Page 70
9. ANOMALIES AND FUNCTIONING When the compressor stops working, the LEDs flash every second (1 sec.) To signal the following anomalies: CODE DESCRIPTION LED1 LED2 LED3 POSSIBLE CAUSE Normal a. the outdoor coil sensor connect loose; Outdoor coil temperature sensor ...
Page 71
9. ANOMALIES AND FUNCTIONING The LEDs flash every 2 seconds (2 sec.) To indicate the following anomalies: CODE DESCRIPTION LED1 LED2 LED3 POSSIBLE CAUSE Protection against overheated a. Radiator sensors fail × × outdoor radiator b. Detection circuit of the sensor on the control panel fails a.The pressure switch fails b.
Page 72
9. ANOMALIES AND FUNCTIONING 9.2 Indications visible on the outdoor units control board X-REVO - XX19 XE , X-REVO - XX19 EX The error codes are indicated by the type and number of flashes of the LEDs on the outdoor unit control board, as better specified below: Models X-REVO-0919EX, X-REVO-1219EX, X-REVO-1819EX: LED1 indicates the first digit of the error code number, LED2 indicates the second digit of the error code and LED3 indicates an error of the outdoor unit inver- ter board.
Page 73
9. ANOMALIES AND FUNCTIONING Models X-REVO-1419DE, X-REVO-1819DE: There are 5 LEDs on the main control board of the outdoor unit, LED1, LED2, LED3, LED4 and LED7. LED1 is the power indicator for the outdoor unit. LED2 and LED3 indicate an error on the main control board of the outdoor unit (LED2 indicates the first digit of the error code,...
Page 74
9. ANOMALIES AND FUNCTIONING For example, error of outdoor unit main control board (code 32): 600 ms 600 ms 600 ms 600 ms 600 ms 600 ms LED2 ON OFF ON OFF ON ON OFF ON OFF ON 600 ms 600 ms 5000 ms 500 ms...
Page 75
9. ANOMALIES AND FUNCTIONING Warning! Switch off the air conditioner with the remote control. Before carrying out any work on the units, make sure that the general power supply has been removed. Error codes referring to the outdoor unit: Cod. Error Description Possible causes How to deal with...
Page 76
9. ANOMALIES AND FUNCTIONING Cod. Error Description Possible causes How to deal with Note Application 1. Normally protection of three- 1.Three-phase power is abnormal; 2. Check the wiring connection refer to phase Voltage absent phase 2.The outdoor wiring connect wrong; the wiring diagram;...
Page 77
9. ANOMALIES AND FUNCTIONING Cod. Error Description Possible causes How to deal with Note 1.Reconnect the cable between the 1.The cable between the control board control board and the driver board; and the driver board connect loose; IPM and control 2.Replace the communication cable 2.The cable between the control board board...
Page 78
9. ANOMALIES AND FUNCTIONING Error codes referring to the indoor unit: Error Description Causes How to Deal With code 1.1 Check whether there are something to block the drain hose or the height of the drain hose is too high; 1.
Page 79
9. ANOMALIES AND FUNCTIONING Error Description Causes How to Deal With code FE (254) Communication 1. The wiring between the wiring controller to the 1.Reconnect the wiring between the wiring controller to between main indoor control board connect loose; the indoor control board; control board 2.
Page 80
9. ANOMALIES AND FUNCTIONING Note 1: When the indoor unit does not turn on, or the indoor unit turns itself off after 30 seconds, it cannot display the error code. Check the connection of the control board. Note 2: If the indoor unit displays the error code 75,76,77,78 after turning on the unit, check that there is no short circuit. Note 3: Overload in cooling mode Cause...
Page 81
9. ANOMALIES AND FUNCTIONING Error code inverter (driver) board Models X-REVO-0919EX, X-REVO-1219EX, X-REVO-1819EX, X-REVO-1419DE, X-REVO-1819DE On the inverter board there is a light that flashes in case of anomalies. The number of flashes indicates the error code Error Description Possible Causes How to Deal With code Inverter DC voltage overload fault...
Page 82
9. ANOMALIES AND FUNCTIONING Error code inverter (driver) board Models X-REVO-2419TE, X-REVO-3619QE On the inverter board there is a light that flashes in case of anomalies. The number of flashes indicates the error code Error Description Possible Causes How to Deal With code 1.
Page 83
9. ANOMALIES AND FUNCTIONING Codice Descrizione Errore Possibile Causa Cosa fare 1. Voltage input too low ; 1. Check the power supply. Low DC voltage 200V 2. Driver board fault. 2. Change the driver board. Driver board read EE data 1.
Page 85
10. ELECTRICAL DIAGRAMS 1. DESCRIZIONE DEI COMPONENTI Electric diagrams OUTDOOR UNIT - 9, 12, 18 kBtu X-REVO-0919EX , X-REVO-1219EX , X-REVO-1819EX...
Page 86
10. ELECTRIC DIAGRAM Electric diagrams OUTDOOR UNIT - DUAL 14 kBtu X-REVO 1419DE / 18 kBtu X-REVO 1819DE...
Page 87
10. ELECTRIC DIAGRAM Electric diagram TRIAL 24 kBtu - X-REVO-2419TE...
Page 88
10. ELECTRIC DIAGRAM Electric diagrams QUADRIAL 36 kBtu - X-REVO-3619QE...
Page 89
11. REFRIGERATION CIRCUIT 1. DESCRIZIONE DEI COMPONENTI SINGLE 9, 12, 18, 24, kBtu Outdoor unit Indoor Unit SIDE GAS Valve Valve 3-way 4-way Silencer Drain Exchanger heat Accumulator (Evaporator) Suction Compressor Exchanger SIDE heat LIQUID (capacitor) Filter Electronic / capillary Filter Valve expansion valve...
Page 90
IT IT 11. REFRIGERATION CIRCUIT 1. DESCRIZIONE DEI COMPONENTI DUAL 14, 18, kBtu Indoor Unit Outdoor unit Unit A Valve 4 way Unit B Unit B Filter Unit A Cooling cycle Heating cycle TRIAL 24 kBtu / QUADRIAL 36 kBtu Indoor Unit Outdoor unit Unit A...
Page 91
8 days of their discovery, unless otherwise agreed in writing and confirmed by both the parties. EMMETI spa Via brigata Osoppo, 166 - 33074 Vigonovo frazione di Fontanafredda (PN) - Italia - Tel.0434567911 - Fax0434567901 - www.emmeti.com...
Page 92
GUARANTEE CERTIFICATE Slip A Model Serial Number Date installation/first running Seller Slip “A” for End User To be kept Company (Please print in block Street letters). Town Country To make the guarantee valid we ask you to follow the below rule: - Fill in the Certificate of Guarantee in a clear and readable way, by Installer.
Page 96
For a correct disposal, the different materials must be divided and collected according to the regulations in force. EMMETI Spa Via B. Osoppo, 166 - 33074 Fontanafredda frazione Vigonovo (PN) Italy Tel. 0434-567911 - Fax 0434-567901 Internet: http://www.emmeti.com - E-mail: info@emmeti.com...