4.6 - Diagnostic
A number of parameters, including the current absorption or motor speed, can be viewed at any time using this function. Proceed as follows:
14A
DIAGNOSTIC
4.7 - Customising the system - BASIC SETTINGS
If necessary, users may select the BASIC SETTINGS, which allow
modification of the control unit's basic parameters.
PARAMETERS
Automatic reclosure time (0 = off)
AUTOMATIC
1
Seconds of delay before the gate recloses automatically
CLOSING TIME
after opening
Reclosing time after transit (0 = off) Seconds of delay
AUTOMATIC
before the gate recloses automatically after excitation of
2
CLOSING AFTER
photocell 1 during opening or with the gate open.
TRANSIT
Motor sensitivity, sensitivity when detecting an obstacle.
3
1 = minimum sensitivity, maximum force on obstacle
SENSITIVITY
10 = maximum sensitivity, minimum force on obstacle
Motor speed during opening
1 = minimum
2 = low
OPENING
4
SPEED
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase.
1 = minimum
2 = low
SLOW DOWN
5
OPENING SPEED
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
6
CLOSING SPEED
3 = medium
4 = high
5 = maximum
MOTOR 1 CURRENT (mA)
MOTOR 2 CURRENT (mA)
MOTOR 1 POSITION (%)
MOTOR 2 POSITION (%)
MOTOR 1 SPEED (%)
MOTOR 2 SPEED (%)
TOTAL CYCLES (CYCLES)
CYCLES LEFT BEFORE SERVICE
SOFTWARE VERSION
Proceed as follows:
14A
DESCRIPTION
BASIC
SETTINGS
DEFAULT
MIN.
0
0
0
0
3
0
4
1
1
1
4
1
EN
MAX.
UNIT
900
s
30
s
10
5
5
5
25