26 ghz pulse burst radar level transmitter

Advertisement

T R A N S M I T T E R
F U N C T I O N A L / P H Y S I C A L
System Design
Measurement Principle
Input
Measured Variable
Span
Output
Type
Resolution
Loop Resistance
Diagnostic Alarm
Diagnostic Indication
Damping
User Interface
Keypad
Display
Digital Communication
Menu Languages
Voltage (Measured at instrument terminals)
Housing
Material
Net/Gross Weight
Overall Dimensions
Cable Entry
SIL 2 Hardware (Safety Integrity Level)
E N V I R O N M E N T
Ambient Operating Temperature
Storage Temperature
Humidity
Electromagnetic Compatibility
Surge Protection
Shock/Vibration
S P E C I F I C A T I O N S
Pulse Burst Radar 26 GHz
Level, determined by the time-of-flight of radar pulse reflections
0.5 to 130 feet (0.2 to 40 meters)
4 to 20 mA with HART: 3.8 mA to 20.5 mA useable (per NAMUR NE43)
F
OUNDATION
Analog:
.003 mA
Digital Display:
1 mm
GP/IS:
591 ohms @ 24 VDC and 22 mA
XP/Flameproof:
500 ohms @ 24 VDC and 22 mA
Selectable: 3.6 mA, 22 mA (meets requirements of NAMUR NE 43), or HOLD last output
Meets requirements of NAMUR NE107
Adjustable 0-10
4-button menu-driven data entry
Graphic Liquid Crystal Display
HART Version 7–with Field Communicator, F
DTM (PACTw re
Transmitter LCD: English, French, German, Spanish, Russian
HART DD: English, French, German, Spanish, Russian, Chinese, Portuguese
F
OUNDATION
HART: General Purpose (Weather proof)/Intrinsically Safe/Explosion-proof:
11 VDC minimum at terminals under certain conditions (refer to Manual 58-603)
FISCO, FNICO, Explosion Proof, General Purpose and Weather Proof
F
OUNDATION
IP67/die-cast aluminum A413 (<0.6% copper); optional stainless steel
Aluminum:
4.5 lbs. (2.0 kg)
Stainless Steel:
10.0 lbs. (4.50 kg)
Refer to page 12
1
" NPT or M20
2
Safe Failure Fraction = 93.2% (HART only)
Functional Safety to SIL 2 as 1oo1 in accordance with IEC 61508
(Full FMEDA report available upon request)
-40 to +175 °F (-40 to +80 °C); LCD viewable -5 to +160 °F (-20 to +70 °C)
-50 to +185 °F (-45 to +85 °C)
0–99%, non-condensing
Meets CE requirement (EN 61326) and NAMUR NE 21
Meets CE EN 61326 (1000V)
ANSI/ISA-S71.03 Class SA1 (Shock); ANSI/ISA-S71.03 Class VC2 (Vibration)
fieldbus
: H1 (ITK Ver. 6.2.0)
), EDDL
fieldbus Host System: English
fieldbus
: 9 to 17.5 VDC
fieldbus
™,
AMS, or FDT
OUNDATION

Advertisement