Identification Nameplate; Identification Code - OBL X9 Series Operating Manual

Process hydraulic diaphragm metering pumps
Table of Contents

Advertisement

Operating manual
5.1

IDENTIFICATION NAMEPLATE

Each pump carries a nameplate for identification. Below is a representation of an example and its position:
1
2
3
Pump identification nameplate
1 = Pump identifying code
2 = OBL Job Number (Order Confirmation)
3 = Pump serial number
4 = Maximum flow rate (l/h with adjustment at 100%)
Ensure that the machinery nameplate, the warning and service adhesives are always present and in good, legible conditions. Otherwise,
provide to replace them.
Removal of the nameplate or alteration of data contained therein is NOT permitted for any reason.
5.2

IDENTIFICATION CODE

The L series version X9 hydraulic diaphragm metering pumps are identified by a code described as follows:
../ LY SX 25 X9A 70 RF FA GS – M...
continue ...
File: UT-4336 – Rev.0
4
5
6
7
Number of pump heads:
NB: Present ONLY for multiple pumps.
Pump type:
LY, LYH, LK, LN, LP
Motor position (seen from the pump head side):
"..." for right-side motor (standard model, no code required)
...SX... for left-side motor
Plunger diameter:
The range differs according to pump model (view "Technical data").
Pumphead execution:
The range differs according to pump model (view "Technical data").
...A... pumphead material: AISI-316L
...P... pumphead material: PVC
...S... pumphead material: PVDF
...T... pumphead material: PTFE
Plunger strokes per minute:
The range differs according to pump model (view "Technical data").
Pump head model:
The range differs according to pump model (view "Technical data").
"..." for operating pressure: 0 ÷ 100 bar (standard model, no code required)
...TS... for operating pressure exceeding 100 bar
Connection type:
The range differs according to pump model (view "Technical data").
...F... UNI-DIN flanged connections
...FA... ANSI flanged connections
...RE... DIN-11851 food industry connections
Adjustment type:
"..." graduate knob and vernier adjustment (standard model, no code required)
...G... gravitational dial adjustment
...GS... gravitational dial with glycerin adjustment
...W... pneumatic actuator adjustment
...WA... pneumatic actuator adjustment with manual adjustment
...Z... electric actuator adjustment
Motor informations:
...M... motors supplied by OBL and assembled on the pump
Copyright © - OBL Metering pumps - All rights reserved
!
Nameplate position on the pump
5 = Hydraulic circuit safety valve pressure calibration (bar)
6 = Year of manufacture
7 = Item (where applicable)
X9 Series metering pumps
GB
Page 9

Hide quick links:

Advertisement

Table of Contents
loading