X9 Series metering pumps
In multiple pumps each pump body has its own lubrication, independent from the others. Operate individually
on each pump body to change all multiple pump lubricating oil.
FIRST lubricant oil change after 1.000 hours of operation. For standard pump version replace oil after every
15.000 operating hours and every 10.000 hours for ATEX pumps. In any case every 5 years.
NOTE: Chemically contaminated lubricants can cause wear, corrosion and leaking seals.
GB
The oil filling plug (pos.119), the oil level plug (pos.120) and the oil drain plug (pos.121) are all placed on the reduction gear body.
The following images allow easy identification of the different plugs.
The oil filling plug (pos.119)
Following table shown quantity and type of lubricant oils suggested:
OIL MAKE
SHELL
ESSO
MOBIL
IP
AGIP
8.

SPECIAL MAINTENANCE

The following guidelines cover the most common "special maintenance" operations that only an expert and trained technician can
perform. Avoid impromptu operations or attempts, contact OBL customer service for specific information.
These maintenance suggestions are not intended as "do-it-yourself" repairs. To perform such works,
specialised technical knowledge is required and operations are to be performed by qualified personnel.
ATTENTION: In the case of dosing anomalies, BEFORE start to dismantling the hydraulic system (pumphead),
verify the actual conditions of pumphead directional valves (see "Valve verify and/or replacement").
Appropriate individual safety devices must always be used to ensure and safeguard the personal safety
of personnel, who must also be properly trained and professionally qualified.
8.1

TECHNICAL DOCUMENTATION

For "special maintenance" not expected, contact OBL customer care (Tel. +39-02-26919.1, info@obl.it) to receive:
detailed and focused informations
-
specific instructions copy (if available)
-
sectional drawing updated copy
-
8.2

HYDRAULIC SYSTEM MAINTENANCE

X9 pump hydraulic system is equipped with an air-bleed valve, a mechanically actuated oil replenishing valve and a safety valve.
The three valves ensure that the pump has:
perfect hydraulic balance, allowing operation without any air bubbles (air-bleed);
-
impossibility of oil overloading due to clogging or shut-off of the suction pipeline, preventing the danger of impact of the
-
diaphragm against the front wall of the pumphead (mechanical replenishing);
displacement recirculation in the event of overpressure or shut-off of the discharge pipeline (safety).
-
Page 28
The oil level plug (pos.120)
OIL TYPE/NAME
OMALA OIL 320
SPARTAN EP 320
MOBILGEAR 632
MELLANA OIL 320
BLASIA 320
Copyright © - OBL Metering pumps - All rights reserved
The oil drain plug (pos.121)
PUMP TYPE
QUANTITY (litres)
LY
LYH
LK
LN
LP
Operating manual
0,85
2,490
3,25
4,75
5,5