ACT365-ACU / ACT365-ACU2A / ACT365-ACUPoE – Installation Instructions

4.3 Defaulting the static IP address

The static IP address can be reset to the default value of 192.168.1.60.
1. Power down the ACT365-ACU Controller.
2. Set the DHCP DIP switch 1 to OFF.
3. Set the DEFAULT DIP switch 2 to ON.
4. Re-apply power.
5. Wait approximately 5 seconds, until the controller confirms default completed by sounding the
buzzer.
6. Remove power.
7. Set the DEFAULT DIP switch 2 to OFF.
8. Re-apply power.
Note: The static IP address can be changed via the web interface.

4.4 Changing static IP address on the ACT365-ACU

1. Connect the ACT365-ACU Controller to the IP network.
2. Open a web browser on a PC (for example, Microsoft Internet Explorer, Google Chrome, etc.).
3. Enter http://<NetBIOS address>, e.g. http://ACT365ACU010049
4. Logon details:
Username: installer
Password: 999999
5. Choose the Communication menu and set the
following:
Static IP Address
l
Network Mask
l
Default Gateway
l
6. Click Save IP Settings.
Note: Use the new IP address when connecting to the
controller.
© Vanderbilt 2019
Ensure nothing is connected to the tamper input terminal and the tamper spring is
not pressed, otherwise the following steps will factory default the controller losing
all information.