PDM+ Single Sustainable Gas Detector User Manual D e t e c t i o n D e t e c t i o n Contents Contents Description Warning Caution Product Overview Activation And Deactivation Mode Detection Mode Display Mode Alarms / Battery / Test Failure display Default Alarm Set Points Default Calibration Gas Concentrations...
LED, vibrating, and audible alarms in the event that gas concentration exceeds alarm set points. The alarm set point, calibration range, and display configuration can be changed via WatchGas IR Link (Optional). After use, the instrument can be turned off.
PDM+ Single Sustainable Gas Detector User Manual D e t e c t i o n D e t e c t i o n Caution • Before operating this device, please read the manual carefully. • This device is not a measurement device, but a gas detector. •...
High Alarm Stabilization Success Stabilization Fail Fresh Air Calibration Standard Gas Calibration Time Weighted Average STEL Short Term Exposion Limit Remaining Months Remaining Days Remaining Time (Hours) Max Peak Value Min Peak Value Unit of Measurement Remaining battery life www.watchgas.eu...
2. Activation & Deactivation Note Information about production dates? Please contact WatchGas by calling +31 (0)85 01 87 709 or by sending us an e-mail to: info@watchgas.nl ACTIVATION AND DEACTIVATION In a safe environment, when pressing and holding the botton (...
Disclaimer: The default Set Points of these gases: H , SO , Cl , NH and NO , are subject to change without notice. NOTE: STEL and TWA functions are unavailable for O and H variants. Alarm values can be locked with the IR link www.watchgas.eu...
LCD. The device will return to the calibration menu. If calibration fails, will appear on the LCD. Check that the air is clean and that no contaminants are blocking the sensor opening and try again. If fresh air calibration fails repeatedly, contact WatchGas.
Press the key for three seconds to initiate calibration. When calibration begins, a countdown will appear on the screen. The duration of the countdown depends on the sensor type and can be change by the IR link (configurable with WatchGas IR-Link). Confirm the calibration value by pressing the button once.
Also make sure that no contaminants are blocking the sensor opening and try again. If standard gas calibration fails repeatedly, contact WatchGas. 5.4. RETURN TO DETECTING MODE. In the standard calibration mode , press the key for a second to toggle fresh air calibration, standard calibration, and ESC.
30 seconds. Stop the flow, remove the calibration adapter. If the test fails, FA message with , will be displayed and BTS message will be flashing until the test is successful. If the bump test repeatedly fails, contact WatchGas. 7. Sensor & Battery Replacement Caution It is absolutely prohibited to replace battery at potential explosion or dangerous regions.
PDM+ Single Sustainable Gas Detector User Manual D e t e c t i o n D e t e c t i o n 7.2. BATTERY REPLACEMENT 1. Deactivate the detector 2. Remove the 6 screws on the back case. 3.
• IEC 60079-0: 2011 Ed. 6 • IEC 60079-11: 2011 Ed 6 • IEC 60079-26 : 2014-10 Ed 3 • EN 60079-0: 2012+A11:2013 • EN 60079-11: 2012 Manufacturing Approval: The detector manufacturer is certified compliant with ISO 9001:2000 provisions www.watchgas.eu...
D e t e c t i o n 10. Limited Warranty WATCHGAS warrants this product to be free of defects in workmanship and materials-under normal use and service-for two years from the date of purchase from the manufacturer or from the product’s authorized reseller.