Dual Spa 2 Integration Kit; Spa 2 Dc Connector Kit - Renishaw apply innovation SPA2 Installation Manual

Servo power amplifier
Table of Contents

Advertisement

12
System description

Dual SPA 2 integration kit

1.2.5
This cable kit is designed to permit a high power solution for CMM installations where the power capacity
of a single SPA 2 will not address the requirements for the machine.
This system enables two SPA 2 units to be combined in a single system and configured to drive the CMM
installation (e.g. if required a single SPA 2 can power a single axis, or if in a dual drive configuration the
two dual axis motors by supplied from separate SPA 2 units and the other two axis be integrated such that
each SPA 2 drives two motors).
This kit contains the following component:
1 off UCC 2 to dual SPA 2 emergency stop connection cable
1.2.6

SPA 2 DC connector kit

This kit has been designed to assist in the connection of either a UCC 2 or UCC lite and SPA 2 to a
machine installation.
This kit contains the following components:
3 off 7W2 motor connectors including backshells to permit connection of the motor and analogue
tacho signals to the SPA 2
1 off 9-way D connector including backshell to permit the connection of an external emergency stop
device to the Renishaw emergency stop chain