Models BP10P3 and BP10PQ1 Battery Powered Impulse Wrenches are designed for use
in assembly operations when a permanent power source is impractical. They are
ideally suited to appliance assembly.
Ingersoll–Rand is not responsible for customer modification of tools for applications on
which Ingersoll–Rand was not consulted.
IMPORTANT SAFETY INFORMATION ENCLOSED.
READ ALL THESE INSTRUCTIONS BEFORE PLACING TOOL IN SERVICE OR
OPERATING THIS TOOL AND SAVE THESE INSTRUCTIONS.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION
IN THIS MANUAL INTO THE HANDS OF THE OPERATOR.
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
WHEN USING ELECTRIC TOOLS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL
PLACING THE TOOL IN SERVICE
Do not remove any labels. Replace any damaged
label.
USING THE TOOL
Always wear eye protection when operating or
performing maintenance on this tool.
Power tools can vibrate in use. Vibration,
repetitive motions, or uncomfortable positions
may be harmful to your hands and arms. Stop
using any tool if discomfort, tingling feeling or
pain occurs. Seek medical advice before resuming
use.
The use of other than genuine Ingersoll–Rand replacement parts may result in personal injury, decreased tool perfor-
mance and increased maintenance, and may invalidate all warranties.
Have your tool repaired by a qualified person. This electric tool is in accordance with the relevant safety requirements.
Repairs should only be carried out by qualified persons using original spare parts; otherwise this may result in consider-
able danger to the user.
Repairs should be made only by authorized, trained personnel. Consult your nearest Ingersoll–Rand Authorized
Servicenter.
Refer All Communications to the Nearest
Ingersoll–Rand Office or Distributor.
 Ingersoll–Rand Company 2000
Printed in Japan
MODELS BP10P3 AND BP10PQ1
INJURY, INCLUDING THE FOLLOWING.
03542370
Guard against electric shock. Prevent body contact
with earthed or grounded surfaces. For example;
pipes, radiators, ranges, refrigerator enclosures.
Keep work area clean. Cluttered areas and benches
invite injuries.
Consider work area environment. Don't expose
power tools and chargers to water. Keep work area
well lighted. Do not use tool in explosive or flam-
mable atmospheres.
Keep bystanders and children away. Do not permit
unauthorized personnel to operate this tool, or touch
tool or battery.
Form P7311
Edition 5
June, 2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BP10P3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ingersoll-Rand BP10P3

  • Page 1 OPERATION AND MAINTENANCE MANUAL FOR MODELS BP10P3 AND BP10PQ1 BATTERY POWERED IMPULSE WRENCHES Models BP10P3 and BP10PQ1 Battery Powered Impulse Wrenches are designed for use in assembly operations when a permanent power source is impractical. They are ideally suited to appliance assembly.
  • Page 2: Warning Label Identification

    WARNING LABEL IDENTIFICATION FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY. WARNING WARNING WARNING Power tools can vibrate in Always wear eye protection use. Vibration, repetitive mo- Always wear hearing when operating or perform- tions or uncomfortable posi- protection when operating ing maintenance on this tions may be harmful to your...
  • Page 3 TOOL AND CHARGER USE AND CARE • When not in use, lock the Trigger Switch by putting AWG SIZE OF CORD FOR LENGTH OF CORD the Forward/Reverse Lever in the neutral (center) position. • Feet Store idle tools. When not in use, tools should be stored in a dry, high or secured place.
  • Page 4: Placing Tool In Service

    • certified for use in Canada. Do not disassemble the Battery. • Model BP10P3–951–EU is certified for use in the Do not store the Battery in locations where the European Common Market temperature may reach or exceed 104_F (40_C). Such locations and conditions might include outside sheds or metal buildings during the summer.
  • Page 5 Use only the models of Battery Chargers listed in the section of this form PLACING THE TOOL IN Changing Rotational Direction SERVICE, for charging the BP10P3–950 Battery. For continuos service of the Impulse Tool, a spare Battery Before operating the Impulse Wrench, make certain the should be kept on hand for alternate use.
  • Page 6 (Dwg. TPA1562–1)
  • Page 7 Front Motor Support ....BP10P3–937 for model BP10P3 ....BP10P3–A40 Front Motor Support Pin (2) .
  • Page 8 EQ104S–933 71 Battery (9.6 volt) ......BP10P3–950 Drive Shaft Assembly (for Model BP10P3) ..
  • Page 9: Maintenance Section

    Spring and Bit Retaining Sleeve (46) off the Drive Shaft (44) and remove the Bit Retaining Ball (45). For Model BP10P3, use a hooked wire to pull the Retaining Pin Spring (52) out of the end of the Drive (Dwg. TPD1265)
  • Page 10 MAINTENANCE SECTION 3. Using a Phillips head screwdriver, remove the four 10. Disassemble the components of the mechanism in the Mechanism Cover Mounting Screws (69). sequence shown in Drawing TPA1562 on Page 7. 4. Lift the Mechanism Cover (66) and the assembled Disassembly of the Gearing and Motor Housing mechanism off the Motor Housing (1).
  • Page 11 MAINTENANCE SECTION 12. Repeat the previous step with the remaining Planet Assembly of the Gearing and Motor Housing Gear on the opposite side of the Gear Frame. 1. Insert the Rear Motor Cushion (13) into the recess in 13. Install the Rear Planet Gear Shaft Retainer (26) on the Motor Housing (1).
  • Page 12 MAINTENANCE SECTION 3. Place a Blade (53) into one of the slots of the Drive The Torque Adjustment Screw (30) can only be Shaft (44) with the Blade Assembly Pins (54) inward. installed from the liner end of the Impulse Housing 4.
  • Page 13 Retaining Ring (49) in the groove on the Shaft. For Model BP10P3, insert the Socket Retaining Pin (51) into the hole in the Drive Shaft and insert the Retaining Pin Spring (52) into the end of the Drive (Dwg.