Using the Y cable EVC843 (→ 4.1) automatically ensures correct wiring�
Connection of the Y cable EVC843:
2
1
5
3
4
1
2
5
4
3
2
1
5
3
4
During parameter setting (→ 8)
1)
10
1: L+ (from the installation)
2: C/Q: IO-Link
to the data
3: L- (from the installation)
splitter (2)
4: switching output OUT1 / IO-Link
5: not connected
1: L+ (from the installation)
2: switching output / analogue output OUT2,
to the IO-Link
device (3)
3: L- (from the installation)
4: C/Q: IO-Link
5: not connected
1: L+ (from the installation)
2: switching output / analogue output OUT2, if
to the
3: L- (from the installation)
installation (4)
4: switching output OUT1 / IO-Link
5: not connected
if available
available
PNP (E43406) or NPN (E43410)