Download Print this page

VERDER HI-CLEAN VA-2H40 Repair Parts page 8

Diaphragm pump
Hide thumbs Also See for HI-CLEAN VA-2H40:

Advertisement

Troubleshooting
Problem
Problem
Problem
Fluid in exhaust air.
Pump exhausts excessive
air at stall.
Pump leaks air externally.
Pump leaks fluid
externally from ball check
valves.
Chattering.
8
Cause
Cause
Cause
Diaphragm ruptured.
Loose diaphragm plate.
Worn air valve block, plate, pilot
block, u-cups, or pilot pin o-rings.
Worn shaft seals.
Loose air valve cover.
Air valve gasket or air cover gasket
is damaged.
Loose air cover clamps
Loose manifolds, damaged seal
between manifold and fluid cover, or
damaged gaskets.
Check valve balls not seating
properly/cleanly due to imbalance
between fluid inlet and outlet line
sizing. Noise is accentuated with
light viscosity fluids.
Solution
Solution
Solution
Replace. See standard or
overmolded diaphragm repair
procedure.
Tighten or replace. See standard
or overmolded diaphragm repair
procedure.
Repair or replace.
Replace. See standard or
overmolded diaphragm repair
procedure.
Tighten screws.
Inspect; replace.
Tighten clamps.
Tighten manifold clamps or replace
seats or clamps.
Reduce size/diameter of inlet line
relative to outlet line. Outlet line size
should not exceed pump size.
812.0064

Advertisement

loading