Download Print this page

VERDER HI-CLEAN VA-2H40 Repair Parts page 13

Diaphragm pump
Hide thumbs Also See for HI-CLEAN VA-2H40:

Advertisement

Disassemble
Disassemble Flapper
Disassemble
Flapper Check
Flapper
1. Follow the
Pressure Relief Procedure, page 9
Disconnect all fluid and air lines.
2. To drain the pump, pull the frame quick-release
pins (207) and rotate the pump.
NOTE: After draining, rotate the pump to
NOTE:
NOTE:
positions which will aid disassembly.
3. Remove the clamps (23) on the outlet manifold
(17) and remove the manifold.
NOTE: Use care while removing manifolds to
NOTE:
NOTE:
avoid damage to check valve components.
812.0064
Check Valves
Check
Valves
Valves
4. Remove remaining clamps (23), manifolds (16
and 17), gaskets (18), and check valves (8).
.
5. Clean and inspect gaskets, flappers, and
seating surfaces for any damage and replace as
necessary.
6. To continue with diaphragm disassembly, see
Disassemble the Standard Diaphragms, page
Reassemble the
the Check
Reassemble
Reassemble
the
NOTE:
NOTE:
NOTE: Lubricate clamps, clamping surfaces, and
gaskets with waterproof, sanitary lubricant.
1. Reassemble check assembly in reverse order.
2. Attach the manifolds to the fluid covers. Tighten
clamps hand tight.
Check Valves
Valves
Check
Valves
Repair
14.
13

Advertisement

loading