Functional Principle, Technical Data
Model
Laser type
Output of measurement values
Control and display elements
Light source
Aperture angle of laser line
Permissible ambient light
Protection class (DIN EN 60529)
Vibration (DIN EN 60068-2-27)
Shock (DIN EN 60068-2-6)
Temperature range
Weight
Supply voltage
1) Based on measuring range; measuring object: Micro-Epsilon standard object
2) According to a one-time averaging over the measuring field (2,048 points)
3) RS422 interface, programmable either as serial interface or as input for triggering/
synchronization
scanCONTROL 30xx
LLT 30x0-25
Red Laser |
Blue Laser
Red Laser
Blue Laser
Laser switch-off
1
(fluorescent light)
LLT 30x0-50
Red Laser |
Blue Laser
Ethernet (UDP / Modbus TCP); RS422 (ASCII / Modbus RTU)
4
4
analog
; switch signal
; PROFINET
3x color LEDs for laser, data and error
≤ 10 mW
Standard: laser class 2M, semiconductor laser 658 nm
≤ 30 mW
Option: laser class 3R, semiconductor laser 658 nm
Standard: laser class 2M, semiconductor laser 405 nm
via software, hardware switch-off with /SI option
23°
28°
IP67 (when connected)
2 g / 20 ... 500 Hz
15 g / 6 ms
Storage: -20 ... +70 °C; Operation: 0 ... +45 °C
415 g (without cable)
11 ... 30 VDC, nominal value 24 V, 500 mA,
IEEE 802.3af class 2, Power over Ethernet (PoE)
4) Only with 2D/3D Output Unit
5) Only with 2D/3D Gateway
LLT 30x0-100
Red Laser |
Blue Laser
5
5
; EtherCAT
; EtherNet/IP
≤ 50 mW
≤ 10 mW
30°
10,000 lx
LLT 30x0-200
Red Laser
5
≤ 12 mW
45°
Page 16