Keysight Technologies PXA N9030A Installation Note

Keysight Technologies PXA N9030A Installation Note

Rack slide kit
Hide thumbs Also See for PXA N9030A:

Advertisement

Quick Links

Keysight PXA Signal Analyzers
Rack Slide Kit
Installation Note

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXA N9030A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keysight Technologies PXA N9030A

  • Page 1 Keysight PXA Signal Analyzers Rack Slide Kit Installation Note...
  • Page 2 The information contained in this document is subject to change without notice. Keysight Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3 Rack Slide Kit Installation Note Rack Slide Kit Installation Note Products Affected: PXA N9030A/N9030B Serial Numbers: To Be Performed By: (X) Keysight Service Center (X) Personnel Qualified by Keysight (X) Customer Estimated Installation Time: 1.0 Hours This retrofit kit provides all parts and instructions for installing the rack slide kit into a standard Keysight rack.
  • Page 4 Rack Slide Kit Installation Note Procedure Remove the instrument bottom feet Remove the bottom feet by pulling out the black plastic locks, lifting the tabs on the feet, and sliding to disengage from the outer case. Remove the instrument strap handles Remove the handles from both sides of the instrument using a Torx -20 driver.
  • Page 5 Rack Slide Kit Installation Note 5. Attach the inner slide by inserting two M 5 x 20 mm screws through the slide and through the spacer and secure to the instrument using a Torx-25 driver. Torque to 21 in-lbs. Figure 2 shows the positioning of the inner slide on the instrument.
  • Page 6 Rack Slide Kit Installation Note Install the outer slide in the instrument rack 1. Assure the left and right side outer slides are identified before attaching to the instrument rack. To do this, install the outer slide onto the inner slide to test the fit. The spring loaded buttons on the slides are offset, and you must check carefully to determine that the spring loaded buttons will align with the holes in the slides.
  • Page 7 It is normal to experience some resistance as the instrument is slid into the rack. For assistance, contact your nearest Keysight Technologies Sales and Service Office. To find your local Keysight office access the following URL, or if in the United States, call the following telephone number: http://www.keysight.com/find/assist...
  • Page 8 This information is subject to change without notice. © Keysight Technologies 2010-2019 Edition 1, July 2019 N9030-90020 www.keysight.com...

This manual is also suitable for: