Specifications
Sensor type
Number of sensors
Measuring point
Recommended max. operating temperature
Type K
Type J
Sheath diameter
Sheath material
Permissible temperatures
Kapton
Fibreglass
PTFE
PVC
Versions
Standard lead length
Process connections
For further specifications see WIKA data sheet TE 65.46 and the order documentation.
WIKA operating instructions model TC46
Model TC46
Type K
Type J
Single thermocouple
Dual thermocouple
Isolated (ungrounded)
Non-isolated (grounded)
1,200 °C [2,192 °F]
800 °C [1,472 °F]
0.5 mm
1.0 mm
1.5 mm
1.6 mm
2.0 mm
3.0 mm
Stainless steel
Ni alloy 2.4816 (Inconel 600)
-25 ... +260 °C [-13 ... +500 °F]
-50 ... +482 °C [-58 ... +900 °F]
-50 ... +260 °C [-58 ... +500 °F]
-20 ... +105 °C [-4 ... +221 °F]
Connecting individually insulated lead wires to the
conductors of the sensor
Connecting pair of insulated lead wire to the
conductors of the sensor
Optional connectors can be attached to the sensor
conductors
1,000 mm [39"] with additional intervals of 500 mm [20"]
Formed / bent sensor
Union screw connection
Spring-loaded connection