Specifications - WIKA GD-20 Series Operating Instructions Manual

Gas density sensor
Hide thumbs Also See for GD-20 Series:
Table of Contents

Advertisement

Available languages

Available languages

9. Specifications

9. Specifications
Digital sensor technology, model GD-20-D
Compensated pressure
range in bar abs. at 20 °C
[68 °F] (g/l SF₆)
0 ... 2 (12.28)
0 ... 3 (18.65)
0 ... 8 (53.4)
0 ... 10 (68.96)
0 ... 12 (85.79)
0 ... 16 (124.64)
Accuracy specifications
Accuracy
1)
Compensated pressure range in
bar abs. at 20 °C [68 °F] (g/l SF₆)
0 ... 2 (12.28)
0 ... 3 (18.65)
Compensated pressure range in
bar abs. at 20 °C [68 °F] (g/l SF₆)
0 ... 8 (53.4)
0 ... 10 (68.96)
0 ... 12 (85.79)
0 ... 16 (124.64)
Pressure accuracy
Temperature accuracy
Reference conditions
1) Specifications apply to measurement of the compensated pressure over the entire temperature range from
-40 ... +80 °C [-40 ... +176 °F]; valid only for pure SF₆ gas and a gas mixture consisting of 6 % Novec 4710, 5 %
O₂ and 89 % CO₂.
WIKA operating instructions gas density sensor, model GD-20
Pressure in
Temperature
bar abs.
0 ... 2.4
-40 ... +80 °C
[-40 ... +176 °F]
0 ... 3.7
0 ... 10.1
0 ... 12.9
0 ... 15.7
0 ... 21.3
For -40 ... -20 °C [-40 ... -4 °F]
For -20 ... +80 °C [-4 ... +176 °F]
For -40 ... -20 °C [-40 ... -4 °F]
For -20 ... +80 °C [-4 ... +176 °F]
±1 % at 20 °C [68 °F] (standard)
±0.2 % at 20 °C [68 °F] (option)
±1,5 K
Per IEC 61298-1
Output
Output
parameters
signal
Density
Modbus
Pressure at
RTU
20 °C [68 °F]
Pressure
Temperature
±2 % (standard)
±1.25 % (option)
±1.5 % (standard)
±0.75 % (option)
±1.25 % (standard)
±0.75 % (option)
±1.25 % (standard)
±0.6 % (option)
EN
®
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gd-20-aGd-20-d

Table of Contents