Monitor Specifications; Mechanical Installation; Gateway - Watts BLUCHER Connected Roof User Manual & Installation Manual

Table of Contents

Advertisement

4.3

Monitor specifications

Power supply
Battery
Battery life
Level Sensor
Sensor electrodes
Enclosure
IP protection
Material
Size
Environmental
Working temperature
Storage temperature
5

Mechanical installation

5.1

Gateway

We recommend that the Gateway is placed centrally in relation to the Monitors, and in line
of sight to ensure the best possible signal strength. Please note that obstructions such as
concrete and metal can reduce the signal range.
Do not install the BLÜCHER
The ambient temperature should be in the range between -10 °C and 55 °C and the humidity below 80% non-condensing.
Please consider the material/thickness of the gateway enclosure for maximized signal strength.
Connected Roof Gateway in areas with a risk of water exposure and high humidity levels.
®
Lithium battery LS 14500 3.6V (internal) AA
Up to 10 years
Stainless A2
IP68
Anti-UV PC
120 x 65 x 60mm
-35°C - 85°C
-35°C - 85°C
REV. 01 - OCTOBER 2020 - BLÜCHER
Temperature
-10 – 55°C
Humidity
< 80% - non
condensing
7
CONNECTED ROOF
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

900.000.400900.100.400

Table of Contents