Installation, Operation, and Maintenance Manual
CSM - Model 28062
Copper Silver Monitor
Rev 1
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can
result in death, serious personal injury, property damage, or
damage to the equipment.
Keep this Manual for future reference.
IS-HF-CSM-100184

Advertisement

Table of Contents
loading

Summary of Contents for Watts HF Scientific CSM

  • Page 1 IS-HF-CSM-100184 Installation, Operation, and Maintenance Manual CSM - Model 28062 Copper Silver Monitor WARNING Read this Manual BEFORE using this equipment. Failure to read and follow all safety and use information can result in death, serious personal injury, property damage, or damage to the equipment.
  • Page 2: Table Of Contents

    Table of Contents 1.0 Understanding Safety Information ..........3 2.0 Introduction to the Unit ..............4 2.1 Overview..................4 2.2 Specifications ................4 2.3 Unpacking and Inspection of the Instrument ......4 2.4 Instrument Labels ..............4 2.5 Display ..................4 3.0 Installation ..................
  • Page 3: Understanding Safety Information

    1.0 Understanding Safety Information This manual contains safety and use instructions that must be followed during the installation, commissioning, operation, care and maintenance and service of the CSM. All responsible personnel must read this manual prior to working with this instrument and should familiarize themselves with the following safety symbols, signals and pictorials.
  • Page 4: Introduction To The Unit

    2.0 Introduction to the Unit 2.4 Instrument Labels The following labels should be applied to the outside of the enclosure. 2.1 Overview Purpose Location Label The CSM (Copper Silver Monitor) has been specially designed to Serial number, manufacturer, Side of Unit measure and report the concentration of copper and silver dosing part number, power rating, in water samples over specified ranges from an ionization system.
  • Page 5: Plumbing Connections

    Low Voltage Connections 3.2 Plumbing Connections All of the low voltage electrical communication connections to the instrument are made at the termination area located on the middle NOTICE It is recommended to install pressure regulating and relief valves to maintain proper inlet pressure for the instrument. Contact HF scientific Customer Service to order pressure regulators and relief valves.
  • Page 6: Mains Power Connections

    5.0 Instrument Configuration WARNING The instrument has the ability to be customized at any time during To minimize the risk of receiving an electrical shock, there is an operation. Configuration Mode has been split into sub-menus to earth stud located outside of the enclosure on the right side. facilitate instrument configuration.
  • Page 7: Setting The Units Of Measurement

    5.4 Adjusting the Brightness 5. Once all outputs have been saved, press the button to return to the home screen or press Cancel to return to the previous menu. The screen brightness can be adjusted to provide easier readability of the display in low light or no light conditions.
  • Page 8: Setting The Reading Mode

    5.6 Setting the Reading Mode 5.8 Security Setting The CSM has 2 different modes of taking readings, The first is Auto The CSM has a security setting that when enabled will only allow Mode. In Auto Mode, measurements are taken at a preset time interval authorized users with a valid numeric password to configure the and displayed on the Home screen.
  • Page 9: Firmware Update

    5.9 Firmware Update 5.10 Copying FRAM data to SD Card Software for the CSM can be updated using an SD card. While the The following information from the CSM can be transferred to an SD software is being updated, it is important to not turn off power to card in CSV file format.
  • Page 10: Factory Reset

    6.0 System Start Up 5.11 Factory Reset To reset all settings to factory defaults: Once all plumbing connections have been made, the CSM is turned on and all configurations have been completed, it is ready for use. 1. Press Factory Reset on the Configuration Menu screen. 2.
  • Page 11: Taking Readings

    7.0 Maintenance 4. A status message will appear letting you know priming is in progress. 7.1 Calibration The CSM was tested and calibrated prior to leaving the factory. The instrument operates from a predetermined calibration curve for high accuracy. Calibration is recommended every 3 months or every time the reagents are replaced.
  • Page 12: Accessories And Replacement Parts List

    4. Disconnect the upper inlet tubing hose from the peristaltic pump and 9. The instrument will take 1 silver reading and 1 copper reading and attach a single piece of black tubing included in the calibration kit to store the reading as calibration data. When the reading is captured, the upper inlet on the peristaltic pump.
  • Page 13: Maintenance

    9.0 Maintenance 9.1 Replacing the Reagent Tubing (Kit #28162S) 9. Ensure duckbill was attached to injector upon removal. If not, remove duckbill from connection on optical assembly. To replace the reagent tubing on the CSM instrument: Remove Velcro strap Duckbill (on injector side of tubing only) Loosen thumb 10.
  • Page 14: Replacing The Reagent Pump (Kit #28167S)

    9.2 Replacing the Reagent Pump 9.3 Replacing the Peristaltic Pump (Kit #28167S) (Kit #28141S) NOTICE To replace the peristaltic pump on the CSM instrument: Take note of the orientation of the check valves and tubing. The 1. Push tabs in on sides and pull up to placement of these items depends on the orientation of the pump remove the pump head from the base.
  • Page 15: Replacing The Air Pump (Kit #28164S)

    10. Place the regulator back into the brackets and secure into place 8. Unscrew black fitting from air pump. with panel nut. 9. Unscrew 2 screws from underneath air pump bracket. 11. Reattach bracket and attached components to the back panel and 10.
  • Page 16: Replacing The Solenoid Valve

    11.0 Warranty Watts Regulator Co. (the “Company”) warrants each municipal market instrument product to be free from defects in material and workmanship under normal usage for a period of one (1) year from first use or two (2) years from date of the Company’s invoice from the original sale of the product, whichever occurs first.