2
Drill Thrubolt
Holes
only have narrower hole.
Strike Lip
For installation assistance contact Corbin Russwin
1-888-607-5703 • support@corbinrusswin.com
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
Mortise Lock Door Preparation & Installation
13. Remove lockbody from door.
14. Drill two thru-bolt holes (9/16") halfway
through one side of door.
15. Drill two thru-bolt holes (9/16") through from
opposite side of door.
NOTE:
DRILL THROUGH BOTH SIDES OF DOOR FOR
BETTER ACCURACY .
16. TURN-PIECE FUNCTIONS ONLY:
Drill one middle hole (.290") and two outer holes
(3/8") halfway through door. (Figure 11)
17. COIN-TURN FUNCTIONS ONLY:
Drill two holes (1/8") halfway through door.
(Figure 12)
18. TURN-PIECE FUNCTIONS ONLY:
Install turn-piece thru-bolt plate using truss
head screw. (Leave screw slightly loose.)
(Figure 13)
NOTE:
THE THRU-BOLT PLATE IS INSTALLED INSIDE
THE DOOR POCKET .
19. Insert mortise lockbody into door and loosely
tighten 1" lock mounting combination screws.
NOTE:
MAKE SURE LOCK
MAKE SURE LOCK IS UNLOCKED . (FIGURE 14)
IS UNLOCKED
Un-Locked
Locked
Figure 14
Figure 11
Thru-bolt
4
Ø3/8"
Ø.290"
Ø3/8"
Ø1/8"
Ø1/8"
Figure 12
Plate
Figure 13
FM352 10/18